Error Code Lookup, by Code

Every other page here is organised by brand, which assumes you know which make you are standing in front of. If you have a code and not a brand, start here. 337 codes from 36 manufacturers' service manuals.

82 of these codes mean different things on different makes. E1 is low ice production on a Hoshizaki, a cabinet probe failure on a True, and an air temperature sensor fault on a Hatco. Match the brand before you act on the meaning, or you will diagnose the wrong machine confidently.

Codes that mean more than one thing

These are the ones worth checking the badge on the machine first.

CodeMakeMeans
000 True T-series and GDM reach-ins Probe open circuit and probe closed circuit respectively
Perlick BBS/SDB and HP-series units Probe open circuit and probe closed circuit
1 Scotsman Prodigy series cubers Long freeze cycle. FLASHING means max freeze exceeded and retrying; STEADY means shut down
Scotsman Flaker/nugget machines No ice sensed: retrying
Scotsman Flaker/nugget machines No ice sensed: shut down
1 FLASH Berkel X13 slicers High temperature detected on the control board
Baxter OV500 rotating rack ovens Air flow fault
2 Scotsman Prodigy series cubers Long harvest cycle. FLASHING means retrying; STEADY means shut down
Scotsman Flaker/nugget machines Auger motor high load
2 FLASHES Berkel X13 slicers Overcurrent detected in the control board
Baxter OV500 rotating rack ovens Flame fault with no call for heat
3 Scotsman Prodigy series cubers No water sensed
Scotsman Flaker/nugget machines No water in reservoir
Blodgett BCT and BLCT combis Boiler high limit tripped: the boiler went above 275F
3 FLASHES Pitco Solstice and SG/SSH fryers Temperature probe open or shorted
Berkel X13 slicers Knife motor over temperature
Baxter OV500 rotating rack ovens Ignition module lockout after three failed trials for ignition
4 Scotsman Prodigy series cubers High discharge temperature
Scotsman Flaker/nugget machines Refrigeration pressure too high or low
Blodgett BCT and BLCT combis Cavity overheat switch off: the oven chamber went above 662F
5 Scotsman Prodigy series cubers Sump temperature sensor failure
Blodgett BCT and BLCT combis Fan motor above 248F
7 Scotsman Prodigy series cubers Discharge temperature sensor failure
Blodgett BCT and BLCT combis Oven chamber temperature probe broken. The oven cannot be used
7 FLASHES Pitco Solstice and SG/SSH fryers Drain valve interlock open
Berkel X13 slicers Unable to find home position
8 Scotsman Prodigy series cubers Short freeze, thin ice. FLASHING means retrying; STEADY means shut down
Blodgett BCT and BLCT combis Core probe broken or not connected properly
A1 Turbo Air Reach-ins and Merchandisers HIGH TEMPERATURE alarm. Corrected: this is not the door alarm
Heatcraft Beacon II Walk-In Systems High box temperature alarm
A2 Turbo Air Reach-ins and Merchandisers Low temperature alarm
Heatcraft Beacon II Walk-In Systems Low box temperature alarm
A4 Turbo Air Reach-ins and Merchandisers Door alarm. This is the code our table previously attributed to A1
Heatcraft Beacon II Walk-In Systems Input fault: box temperature, suction temperature or pressure transducer open or not installed
AH1 Perlick BBS/SDB and HP-series units Eliwell controller: probe 1 high temperature alarm
Beverage-Air WTR, UCR and HF cabinets Cabinet temperature too warm
B Scotsman Prodigy series cubers The letters the display shows in normal operation
Scotsman Flaker/nugget machines Bin full, ice making paused
BLUE OFF Gaylord CG3-UVi water-wash ventilators One or more UV lamps are not working
Gaylord CG3-UVi water-wash ventilators No power reaching the UV ballast
C Scotsman Prodigy series cubers The letters the display shows in normal operation
Scotsman Flaker/nugget machines Clean cycle running
CA True T-series and GDM reach-ins External alarms of three severities, from a digital input
Perlick BBS/SDB and HP-series units External alarms of three severities, from a digital input
CCC True T-series and GDM reach-ins Probe open circuit and probe closed circuit respectively
Perlick BBS/SDB and HP-series units Probe open circuit and probe closed circuit
D Scotsman Prodigy series cubers The letters the display shows in normal operation
Scotsman Flaker/nugget machines Test mode active
DEA True T-series and GDM reach-ins Defrost ended on TIME rather than on temperature
Perlick BBS/SDB and HP-series units Defrost ended on TIME rather than on temperature
DEF True T-series and GDM reach-ins Defrost in progress (LAE)
Beverage-Air WTR, UCR and HF cabinets The unit is defrosting
Heatcraft Beacon II Walk-In Systems NOT FAULTS. These are the eight normal operating modes
DOOR OPEN Hobart LXi/AM15 door dish machines CL/CLe conveyor text alerts
Hobart LXi/AM15 door dish machines Door is open or not registering as closed
Traulsen Intela-Traul reach-ins Door open: a door has been open longer than the control allows
E Scotsman Prodigy series cubers Self test failed at power-up, and nothing else will happen
Scotsman Flaker/nugget machines Controller self test failed
Stero SD3 door-type dish machines The control keeps the most recent machine fault in service diagnostics even after a power cycle clears the display
E0 Hoshizaki FM-series flakers and F/FD modular flakers Ice making water leak
Hobart LXi/AM15 door dish machines Machine will not fill, or will not fill high enough. The cycle stops and the machine will not run
E01 Manitowoc Indigo/NXT/NEO cubers Long freeze cycle
Alto-Shaam Combitherm combi ovens Steam generator water fill fault
Beverage-Air WTR, UCR and HF cabinets Sensor S1 has failed, short or open. S1 is the air temperature probe
E1 Hoshizaki FM-series flakers and F/FD modular flakers Low ice production
True T-series and GDM reach-ins Cabinet temperature probe failure
Perlick BBS/SDB and HP-series units Probe reading out of range
Beverage-Air WTR, UCR and HF cabinets Sensor S1 has failed, short or open. S1 is the air temperature probe
Hatco Flav-R-Savor holding cabinets Air temperature sensor malfunctioning ON HOLDING CABINETS. On a Hydro-Heater it means something different: see below
Turbo Air Reach-ins and Merchandisers Depends entirely on which controller is fitted, and published sources contradict each other
Heatcraft Beacon II Walk-In Systems Sensor shorted, open or not installed: room, defrost and suction respectively
E02 Manitowoc Indigo/NXT/NEO cubers Long harvest cycle
Alto-Shaam Combitherm combi ovens Control temperature high (CTP/CTC)
Beverage-Air WTR, UCR and HF cabinets Sensor S2 has failed, short or open. S2 is the evaporator coil probe used to terminate defrost
E2 Hoshizaki FM-series flakers and F/FD modular flakers Float switch error
Hobart LXi/AM15 door dish machines Machine will not fill, or will not fill high enough. The cycle stops and the machine will not run
Hobart LXi/AM15 door dish machines Fill did not complete: water failed to reach the tank float within 2.5 minutes (AM Select)
True T-series and GDM reach-ins Evaporator probe failure
Perlick BBS/SDB and HP-series units Defrost probe and third probe faulty
Stero SD3 door-type dish machines Water did not reach the float during fill within 150 seconds
Beverage-Air WTR, UCR and HF cabinets Sensor S2 has failed, short or open. S2 is the evaporator coil probe used to terminate defrost
Hatco Flav-R-Savor holding cabinets Humidity temperature sensor malfunctioning ON HOLDING CABINETS. On a Hydro-Heater it is the control probe: see below
Turbo Air Reach-ins and Merchandisers The clearest example of the contradiction, and worth checking carefully
Heatcraft Beacon II Walk-In Systems Sensor shorted, open or not installed: room, defrost and suction respectively
E03 Manitowoc Indigo/NXT/NEO cubers Input power loss
Frymaster M3000 controller fryers Temperature probe failure
Alto-Shaam Combitherm combi ovens Fan motor error (CTP/CTC)
Beverage-Air WTR, UCR and HF cabinets Sensor S3 has failed, short or open
E3 Hoshizaki FM-series flakers and F/FD modular flakers Gear motor error or gear motor sensor circuit open
Hobart LXi/AM15 door dish machines Machine will not fill, or will not fill high enough. The cycle stops and the machine will not run
True T-series and GDM reach-ins Auxiliary or display probe failure
Perlick BBS/SDB and HP-series units Defrost probe and third probe faulty
Beverage-Air WTR, UCR and HF cabinets Sensor S3 has failed, short or open
Hatco Flav-R-Savor holding cabinets The low water probe has not been satisfied and the heating elements are not yet submersed
Heatcraft Beacon II Walk-In Systems Sensor shorted, open or not installed: room, defrost and suction respectively
E04 Manitowoc Indigo/NXT/NEO cubers High condenser temperature or water condenser fault
Frymaster M3000 controller fryers High limit reading out of range
Alto-Shaam Combitherm combi ovens Lower fan motor error, two-motor models (CTP/CTC)
Beverage-Air WTR, UCR and HF cabinets Sensor S4 has failed, short or open
E4 Hoshizaki FM-series flakers and F/FD modular flakers Abnormal high side pressure
Hobart LXi/AM15 door dish machines Machine will not fill, or will not fill high enough. The cycle stops and the machine will not run
Beverage-Air WTR, UCR and HF cabinets Sensor S4 has failed, short or open
Heatcraft Beacon II Walk-In Systems Suction pressure transducer shorted, open or not installed
E05 Manitowoc Indigo/NXT/NEO cubers High-pressure control opened
Frymaster M3000 controller fryers High limit temperature exceeded
Alto-Shaam Combitherm combi ovens VFD communication failure (CTP/CTC)
E5 Hoshizaki FM-series flakers and F/FD modular flakers Gear motor drive element error
Hobart LXi/AM15 door dish machines Machine will not drain, or is filling too high and leaking from the door
Heatcraft Beacon II Walk-In Systems Outdoor temperature sensor shorted
E06 Frymaster M3000 controller fryers Heating failure
Alto-Shaam Combitherm combi ovens VFD communication failure, second drive (CTP/CTC)
E6 Hobart LXi/AM15 door dish machines Control fault with no operator remedy published (AM Select)
Stero SD3 door-type dish machines The float and temperature thermistors could not be detected at all
Turbo Air Reach-ins and Merchandisers Fault in the real-time clock
Heatcraft Beacon II Walk-In Systems Low superheat during cooling, held at 0F for two minutes
E7 Hobart LXi/AM15 door dish machines Water sensors need cleaning
Heatcraft Beacon II Walk-In Systems Compressor shutdown on a safety: high pressure, low pressure or oil pressure
E08 Manitowoc Indigo/NXT/NEO cubers TXV fault
Frymaster M3000 controller fryers ATO board error: the controller has lost contact with the automatic top-off board
E09 Manitowoc Indigo/NXT/NEO cubers Flooding evaporator TXV fault
Frymaster M3000 controller fryers Top-off pump not filling
E10 Manitowoc Indigo/NXT/NEO cubers Flooding evaporator TXV fault
Frymaster M3000 controller fryers Drain valve not open
E11 Manitowoc Indigo/NXT/NEO cubers Refrigeration fault
Frymaster M3000 controller fryers Drain valve not closed
E12 Manitowoc Indigo/NXT/NEO cubers Curtain switch open more than 24 hours
Frymaster M3000 controller fryers Return valve not open
E16 Manitowoc Indigo/NXT/NEO cubers Remote condenser fault
Frymaster M3000 controller fryers Filtration (AIF) probe error
E20 Manitowoc Indigo/NXT/NEO cubers Water system fault
Frymaster M3000 controller fryers Invalid code location: the SD card was removed during a software upgrade
E25 Manitowoc Indigo/NXT/NEO cubers Bin level probe low sensor fault
Frymaster M3000 controller fryers Recovery fault
E27 Manitowoc Indigo/NXT/NEO cubers Bin level probe fault, medium (E26) and high (E27) sensor
Frymaster M3000 controller fryers Low temperature alarm: oil is roughly 35F below setpoint
Turbo Air Reach-ins and Merchandisers Sensor errors on specific inputs: S5, Sair and Saux respectively
E28 Manitowoc Indigo/NXT/NEO cubers AUCS board not detected
Frymaster M3000 controller fryers High temperature alarm
E29 Manitowoc Indigo/NXT/NEO cubers USB communication or download fault
Turbo Air Reach-ins and Merchandisers Sensor errors on specific inputs: S5, Sair and Saux respectively
E30 Manitowoc Indigo/NXT/NEO cubers USB communication or download fault
Turbo Air Reach-ins and Merchandisers Sensor errors on specific inputs: S5, Sair and Saux respectively
E105 Alto-Shaam Combitherm combi ovens Low water pressure or no water
Merrychef eikon speed ovens Supply voltage high or low, OR supply frequency high or low, depending on the model
EA True T-series and GDM reach-ins External alarms of three severities, from a digital input
Perlick BBS/SDB and HP-series units External alarms of three severities, from a digital input
ED Hobart LXi/AM15 door dish machines Slow leak: the tank is losing water (AM Select)
Stero SD3 door-type dish machines Slow leak: the machine refilled three times within 35 minutes of the initial fill
EE Hobart LXi/AM15 door dish machines Final rinse never reached temperature: the booster did not hit setpoint within 8 minutes after initial fill (AM Select)
True T-series and GDM reach-ins Power interruption during fast chill, clock settings lost, memory corruption
Stero SD3 door-type dish machines The booster did not reach temperature within eight minutes of the initial fill
F Scotsman Prodigy series cubers The letters the display shows in normal operation
Scotsman Flaker/nugget machines Freeze mode: the machine is making ice
Stero SD3 door-type dish machines The control keeps the most recent machine fault in service diagnostics even after a power cycle clears the display
F1 TurboChef Tornado rapid cook ovens Blower running status bad
Jackson NXP door-type dish machines The booster is calling for heat with no water in it, which the control blocks to protect the element
Turbo Air Reach-ins and Merchandisers F-sensor and D-sensor malfunction respectively
F2 TurboChef Tornado rapid cook ovens Cook temperature low
Jackson NXP door-type dish machines A heater contactor is not switching off when it should
F3 TurboChef Tornado rapid cook ovens Magnetron current low
Jackson NXP door-type dish machines The machine could not fill
F4 TurboChef Tornado rapid cook ovens Door monitor defective
Jackson NXP door-type dish machines The machine is not receiving power correctly
F5 TurboChef Tornado rapid cook ovens Magnetron over temperature
Jackson NXP door-type dish machines The tank is not reaching temperature
F6 TurboChef Tornado rapid cook ovens Electrical compartment temperature high
Jackson NXP door-type dish machines Same fault as F1 but on the wash tank rather than the booster
F7 TurboChef Tornado rapid cook ovens Thermocouple open
TurboChef Tornado rapid cook ovens Two codes display on screen but are never counted, so the log understates what the oven has been doing
Jackson NXP door-type dish machines A heater contactor is not switching off when it should
F8 TurboChef Tornado rapid cook ovens Heat low fault
Jackson NXP door-type dish machines The machine could not fill
GREEN OFF Gaylord CG3-UVi water-wash ventilators UV system in standby and not operating
Gaylord CG3-UVi water-wash ventilators No power reaching the UV ballast
HA True T-series and GDM reach-ins thi: highest temperature recorded in the LAE log. HA: live high temperature alarm on Dixell models
Perlick BBS/SDB and HP-series units Dixell controller: maximum temperature alarm
HI True T-series and GDM reach-ins Cabinet high temperature alarm (LAE)
Vulcan VK/TR and ER/GR fryers Oil at 415F or above
Pitco Solstice and SG/SSH fryers Oil at an unsafe temperature
Beverage-Air WTR, UCR and HF cabinets Cabinet temperature too warm
HI TEMP Frymaster M3000 controller fryers Three separate over-temperature messages that are easy to confuse
Garland MCO convection ovens The oven is more than 50F above its setpoint, and the heaters have been cut
L Scotsman Prodigy series cubers The letters the display shows in normal operation
Scotsman Flaker/nugget machines Board locked, buttons ignored
LA True T-series and GDM reach-ins tLo: lowest temperature recorded in the LAE log. LA: live low temperature alarm on Dixell models
Perlick BBS/SDB and HP-series units Dixell controller: minimum temperature alarm
LO True T-series and GDM reach-ins Cabinet low temperature alarm (LAE)
Pitco Solstice and SG/SSH fryers Oil below the ready temperature
Beverage-Air WTR, UCR and HF cabinets Cabinet temperature too cold
LOC True T-series and GDM reach-ins Keypad locked (LAE)
Heatcraft Beacon II Walk-In Systems Not a fault. The board is locked and settings cannot be changed
O Scotsman Prodigy series cubers The letters the display shows in normal operation
Scotsman Flaker/nugget machines Machine switched off at the controller
OFF True T-series and GDM reach-ins Controller in standby, refrigeration off (LAE)
True T-series and GDM reach-ins External alarms of three severities, from a digital input
Perlick BBS/SDB and HP-series units External alarms of three severities, from a digital input
Garland MCO convection ovens Not a fault. The oven is off and has cooled below 150F, so the fan relay has opened
Heatcraft Beacon II Walk-In Systems NOT FAULTS. These are the eight normal operating modes
OPEN PROBE Vulcan VK/TR and ER/GR fryers Temperature probe circuit open
Southbend Convection Oven The RTD temperature probe reads open
P1 Hobart LXi/AM15 door dish machines Tank temperature probe out of range
True T-series and GDM reach-ins Cabinet temperature probe failure
Perlick BBS/SDB and HP-series units Dixell controller: probe failure
Stero SD3 door-type dish machines Wash tank thermistor open or shorted
P2 Hobart LXi/AM15 door dish machines Tank temperature probe out of range
True T-series and GDM reach-ins Evaporator probe failure
Stero SD3 door-type dish machines Rinse thermistor open or shorted
P3 Hobart LXi/AM15 door dish machines Rinse temperature probe out of range
True T-series and GDM reach-ins Auxiliary or display probe failure
Stero SD3 door-type dish machines Booster thermistor open or shorted
SHORTED PROBE Vulcan VK/TR and ER/GR fryers Temperature probe shorted
Southbend Convection Oven The RTD temperature probe reads shorted
TEMP SENSOR OUT OF RANGE Bunn Axiom and Infusion Series ICB digital-control brewers The temperature sensor circuit reads open
Bunn Axiom and Infusion Series ICB digital-control brewers The temperature sensor circuit reads shorted
YELLOW ON Gaylord CG3-UVi water-wash ventilators One or more UV lamps are not working
Gaylord CG3-UVi water-wash ventilators No power reaching the UV ballast

Every code, A to Z

CodeMakeMeans
000 True T-series and GDM reach-ins Probe open circuit and probe closed circuit respectively
Perlick BBS/SDB and HP-series units Probe open circuit and probe closed circuit
1 Scotsman Prodigy series cubers Long freeze cycle. FLASHING means max freeze exceeded and retrying; STEADY means shut down
Scotsman Flaker/nugget machines No ice sensed: retrying
Scotsman Flaker/nugget machines No ice sensed: shut down
1 BEEP Hoshizaki FM-series flakers and F/FD modular flakers Low water safety: the reservoir did not refill in time
1 FLASH Berkel X13 slicers High temperature detected on the control board
Baxter OV500 rotating rack ovens Air flow fault
2 Scotsman Prodigy series cubers Long harvest cycle. FLASHING means retrying; STEADY means shut down
Scotsman Flaker/nugget machines Auger motor high load
2 BEEPS Hoshizaki FM-series flakers and F/FD modular flakers Control switch left in DRAIN longer than 15 minutes
2 FLASHES Berkel X13 slicers Overcurrent detected in the control board
Baxter OV500 rotating rack ovens Flame fault with no call for heat
2 OR 3 Stero SD3 door-type dish machines The control's record of which thermistor faulted
2 OR 6 Stero SD3 door-type dish machines The control keeps the most recent machine fault in service diagnostics even after a power cycle clears the display
3 Scotsman Prodigy series cubers No water sensed
Scotsman Flaker/nugget machines No water in reservoir
Blodgett BCT and BLCT combis Boiler high limit tripped: the boiler went above 275F
3 BEEPS Hoshizaki FM-series flakers and F/FD modular flakers High-pressure switch tripped, first or second time within an hour
3 FLASHES Pitco Solstice and SG/SSH fryers Temperature probe open or shorted
Berkel X13 slicers Knife motor over temperature
Baxter OV500 rotating rack ovens Ignition module lockout after three failed trials for ignition
4 Scotsman Prodigy series cubers High discharge temperature
Scotsman Flaker/nugget machines Refrigeration pressure too high or low
Blodgett BCT and BLCT combis Cavity overheat switch off: the oven chamber went above 662F
4 BEEPS Hoshizaki FM-series flakers and F/FD modular flakers High-pressure switch tripped a third time within the same hour
4 FLASHES Berkel X13 slicers Automatic motor internal hall effect malfunction
4 TO 10 Turbo Air Reach-ins and Merchandisers Not equipment faults at all: results of copying settings with a copy key
5 Scotsman Prodigy series cubers Sump temperature sensor failure
Blodgett BCT and BLCT combis Fan motor above 248F
5 BEEPS Hoshizaki FM-series flakers and F/FD modular flakers Freeze timer: 30 minutes elapsed without the lower float opening
5 FLASHES Berkel X13 slicers Automatic motor hall effect transition malfunction
6 Blodgett BCT and BLCT combis Drain temperature above 167F for more than five minutes, against a normal below 140F
6 BEEPS Hoshizaki FM-series flakers and F/FD modular flakers Low supply voltage, at or below 92VAC plus or minus 5%
6 FLASHES Berkel X13 slicers Encoder input not active
7 Scotsman Prodigy series cubers Discharge temperature sensor failure
Blodgett BCT and BLCT combis Oven chamber temperature probe broken. The oven cannot be used
7 BEEPS Hoshizaki FM-series flakers and F/FD modular flakers High supply voltage, at or above 147VAC plus or minus 5%
7 FLASHES Pitco Solstice and SG/SSH fryers Drain valve interlock open
Berkel X13 slicers Unable to find home position
8 Scotsman Prodigy series cubers Short freeze, thin ice. FLASHING means retrying; STEADY means shut down
Blodgett BCT and BLCT combis Core probe broken or not connected properly
8 BEEPS Hoshizaki FM-series flakers and F/FD modular flakers Gear motor alarm: the compressor control relay contacts failed to close
8 FLASHES Berkel X13 slicers Carriage moving too fast or too slow
9 Blodgett BCT and BLCT combis Boiler probe (9) or drain probe (10) not working properly
9 BEEPS Hoshizaki FM-series flakers and F/FD modular flakers Bin control fault: the mechanical backup had to stop the machine
9 FLASHES Berkel X13 slicers Clutch disengaged while running
10 Blodgett BCT and BLCT combis Boiler probe (9) or drain probe (10) not working properly
10 FLASHES Berkel X13 slicers Slide bar guide switch not engaged
11 Blodgett BCT and BLCT combis Not enough water: the steam generator did not fill to high level within two minutes
12 Blodgett BCT and BLCT combis Solid state relay heat sink above 248F
13 Blodgett BCT and BLCT combis Top heating element of the steam generator above 266F
14 Blodgett BCT and BLCT combis Fan rotational speed too slow
15 Blodgett BCT and BLCT combis CPU board (15) or IO board (16) above 140F
16 Blodgett BCT and BLCT combis CPU board (15) or IO board (16) above 140F
20 Blodgett BCT and BLCT combis Communication failure between the computer and the IO board
22 Blodgett BCT and BLCT combis Program interrupted by a power outage long enough that it cannot restart
23 Blodgett BCT and BLCT combis The oven is too hot for CombiWash to start
24 Blodgett BCT and BLCT combis Drain blocked: the steam generator could not be emptied during flushing
25 Blodgett BCT and BLCT combis ClimaOptima humidity faults: not calibrated (25), sensor out of range (26), or calibration did not complete (27)
26 Blodgett BCT and BLCT combis ClimaOptima humidity faults: not calibrated (25), sensor out of range (26), or calibration did not complete (27)
27 Blodgett BCT and BLCT combis ClimaOptima humidity faults: not calibrated (25), sensor out of range (26), or calibration did not complete (27)
29 Blodgett BCT and BLCT combis Door sensor not working properly
34 Blodgett BCT and BLCT combis Water pressure too low
37 Blodgett BCT and BLCT combis CombiWash could not cool to set point (37), or was interrupted with detergent still in the chamber (38)
38 Blodgett BCT and BLCT combis CombiWash could not cool to set point (37), or was interrupted with detergent still in the chamber (38)
45 Blodgett BCT and BLCT combis No 24VAC: the main contactor output is not working
50 Blodgett BCT and BLCT combis Pressure switch errors: active at start when it should not be (50/60), or not active once the gas fan runs (51/61)
51 Blodgett BCT and BLCT combis Pressure switch errors: active at start when it should not be (50/60), or not active once the gas fan runs (51/61)
52 Blodgett BCT and BLCT combis Gas valve failure: the valve did not open after five start attempts
54 Blodgett BCT and BLCT combis Gas fan RPM incorrect before ignition
55 Blodgett BCT and BLCT combis Ignition failure on first attempt, a WARNING only (55/65), or no flame detected after five attempts (56/66)
56 Blodgett BCT and BLCT combis Ignition failure on first attempt, a WARNING only (55/65), or no flame detected after five attempts (56/66)
57 Blodgett BCT and BLCT combis Gas stopped during operation. Warning only
60 Blodgett BCT and BLCT combis Pressure switch errors: active at start when it should not be (50/60), or not active once the gas fan runs (51/61)
61 Blodgett BCT and BLCT combis Pressure switch errors: active at start when it should not be (50/60), or not active once the gas fan runs (51/61)
62 Blodgett BCT and BLCT combis Gas valve failure: the valve did not open after five start attempts
64 Blodgett BCT and BLCT combis Gas fan RPM incorrect before ignition
65 Blodgett BCT and BLCT combis Ignition failure on first attempt, a WARNING only (55/65), or no flame detected after five attempts (56/66)
66 Blodgett BCT and BLCT combis Ignition failure on first attempt, a WARNING only (55/65), or no flame detected after five attempts (56/66)
67 Blodgett BCT and BLCT combis Gas stopped during operation. Warning only
888 ON THE DISPLAY Heatcraft Beacon II Walk-In Systems Supply voltage has fallen below 18 VAC
6100XL Delfield MCII Tempatrol, and 6000XL/6100XL reach-ins The display swaps the temperature read-out for an error read-out
A1 Turbo Air Reach-ins and Merchandisers HIGH TEMPERATURE alarm. Corrected: this is not the door alarm
Heatcraft Beacon II Walk-In Systems High box temperature alarm
A2 Turbo Air Reach-ins and Merchandisers Low temperature alarm
Heatcraft Beacon II Walk-In Systems Low box temperature alarm
A3 Heatcraft Beacon II Walk-In Systems System start-up failure: the compressor tried four times and failed
A4 Turbo Air Reach-ins and Merchandisers Door alarm. This is the code our table previously attributed to A1
Heatcraft Beacon II Walk-In Systems Input fault: box temperature, suction temperature or pressure transducer open or not installed
A45 Turbo Air Reach-ins and Merchandisers NOT FAULTS: standby and case cleaning
A59 Turbo Air Reach-ins and Merchandisers NOT FAULTS: standby and case cleaning
A61 Turbo Air Reach-ins and Merchandisers Condenser temperature alarm
AH1 Perlick BBS/SDB and HP-series units Eliwell controller: probe 1 high temperature alarm
Beverage-Air WTR, UCR and HF cabinets Cabinet temperature too warm
AL1 Perlick BBS/SDB and HP-series units Eliwell controller: probe 1 low temperature alarm
AUTO Garland MCO convection ovens Not a fault. The oven has been switched off while still above 150F, and the fan is running it down
B Scotsman Prodigy series cubers The letters the display shows in normal operation
Scotsman Flaker/nugget machines Bin full, ice making paused
BELT JAM Lincoln Impinger Conveyor Ovens The control cannot prove the conveyor is turning
BLOCKED DRAIN - RETRY Pitco Solstice and SG/SSH fryers Auto-filter fryers: the drain valve is not closing and the controller is not seeing the closed signal
BLUE OFF Gaylord CG3-UVi water-wash ventilators One or more UV lamps are not working
Gaylord CG3-UVi water-wash ventilators No power reaching the UV ballast
BLUE ON Gaylord CG3-UVi water-wash ventilators UV system in standby and not operating
BOOSTER LEVEL SENSOR Hobart LXi/AM15 door dish machines Booster pressure switch out of range
BREW TEMPERATURE TOO LOW Bunn Axiom and Infusion Series ICB digital-control brewers The brewer is refusing to start because the tank is below its ready temperature
C Scotsman Prodigy series cubers The letters the display shows in normal operation
Scotsman Flaker/nugget machines Clean cycle running
C4 Pitco Solstice and SG/SSH fryers Melt cycle in progress: not a fault
CA True T-series and GDM reach-ins External alarms of three severities, from a digital input
Perlick BBS/SDB and HP-series units External alarms of three severities, from a digital input
CALL SERVICE Hobart LXi/AM15 door dish machines Temperature probe fault on the LX40 family, equivalent to P1/P2/P3
CALL SERVICE - ERR Pitco Solstice and SG/SSH fryers Auto-filter fryers: the blocked-drain lockout has been confirmed and the fryer will no longer operate
CAVITY TOO HOT Southbend Convection Oven Averaged cavity temperature reached 650F or higher
CCC True T-series and GDM reach-ins Probe open circuit and probe closed circuit respectively
Perlick BBS/SDB and HP-series units Probe open circuit and probe closed circuit
CHECK FITTINGS FOR LIME Bunn Axiom and Infusion Series ICB digital-control brewers The control has detected flow consistent with scale building up
CHECK FOR BAD CONNECTIONS Bunn Axiom and Infusion Series ICB digital-control brewers The temperature sensor circuit reads open
CHECK FUNNEL Bunn Axiom and Infusion Series ICB digital-control brewers The brewer will not start because the funnel is not right
CHECK SPRAYHEAD FOR LIME Bunn Axiom and Infusion Series ICB digital-control brewers The control has detected flow consistent with scale building up
CHECK SYSTEM Delfield MCII Tempatrol, and 6000XL/6100XL reach-ins Delfield's own wording is that a potentially serious problem has occurred
CHECK WIRE FOR SHORTS Bunn Axiom and Infusion Series ICB digital-control brewers The temperature sensor circuit reads shorted
CHI Traulsen Intela-Traul reach-ins High cabinet temperature: cabinet air has risen above the alarm band and stayed there
CLEAN CONDENSER Delfield MCII Tempatrol, and 6000XL/6100XL reach-ins A maintenance reminder on a 90-day timer, NOT a fault
CLEAN FILTER Traulsen Intela-Traul reach-ins Clean condenser: liquid line temperature reached 140F on R&A series, which Traulsen uses as a dirty-condenser signal
CLEAR CONVEYOR JAM Hobart LXi/AM15 door dish machines CL/CLe conveyor text alerts
CLO Traulsen Intela-Traul reach-ins Low cabinet temperature: cabinet air has fallen below the alarm band
CODE 3 Ice-O-Matic CIM and Elevation cubers Distributor guide numbering, not the board's own: usually described as a thermistor or multi fault code
CODE 5 Ice-O-Matic CIM and Elevation cubers Distributor guide numbering, not the board's own: usually described as a maximum length fill
CODE 33 Convotherm easyTouch combi steamers (OES, OEB, OGS, OGB) Steam generator will not reach its water level
CON Beverage-Air WTR, UCR and HF cabinets Condenser temperature is too high or too low
CONFIRM SHUT DOWN Pitco Solstice and SG/SSH fryers Scrolling confirmation prompt during a blocked-drain lockout
CONTROLS TOO HOT Southbend Convection Oven The control cavity, not the oven cavity, reached 176F or higher
COO Heatcraft Beacon II Walk-In Systems NOT FAULTS. These are the eight normal operating modes
COOL Baxter OV500 rotating rack ovens Cool Down mode is active, which is not a fault
D Scotsman Prodigy series cubers The letters the display shows in normal operation
Scotsman Flaker/nugget machines Test mode active
D1 Turbo Air Reach-ins and Merchandisers F-sensor and D-sensor malfunction respectively
DE-L Hatco Flav-R-Savor holding cabinets The water reservoir needs deliming
DEA True T-series and GDM reach-ins Defrost ended on TIME rather than on temperature
Perlick BBS/SDB and HP-series units Defrost ended on TIME rather than on temperature
DEF True T-series and GDM reach-ins Defrost in progress (LAE)
Beverage-Air WTR, UCR and HF cabinets The unit is defrosting
Heatcraft Beacon II Walk-In Systems NOT FAULTS. These are the eight normal operating modes
DEF ERR Traulsen Intela-Traul reach-ins Defrost error: defrost did not terminate on temperature during a 36 hour period
DEFROST Delfield MCII Tempatrol, and 6000XL/6100XL reach-ins A defrost cycle is running. Not a fault
DLY Heatcraft Beacon II Walk-In Systems NOT FAULTS. These are the eight normal operating modes
DO True T-series and GDM reach-ins Door open alarm
DOOR AJAR Delfield MCII Tempatrol, and 6000XL/6100XL reach-ins A door is open, and after a delay the machine escalates
DOOR OPEN Hobart LXi/AM15 door dish machines CL/CLe conveyor text alerts
Hobart LXi/AM15 door dish machines Door is open or not registering as closed
Traulsen Intela-Traul reach-ins Door open: a door has been open longer than the control allows
DOR Beverage-Air WTR, UCR and HF cabinets Door is open
DR OP Hobart LXi/AM15 door dish machines Door is open or not registering as closed
DRAIN ERROR Hobart LXi/AM15 door dish machines Drain fault
DRAINING TURN OFF Pitco Solstice and SG/SSH fryers The controller believes the drain valve is open
E Scotsman Prodigy series cubers Self test failed at power-up, and nothing else will happen
Scotsman Flaker/nugget machines Controller self test failed
Stero SD3 door-type dish machines The control keeps the most recent machine fault in service diagnostics even after a power cycle clears the display
E-4 Henny Penny OFE/OFG open fryers Control board overheating
E-5 Henny Penny OFE/OFG open fryers Oil overheating
E-6A Henny Penny OFE/OFG open fryers Temperature probe OPEN circuit
E-6B Henny Penny OFE/OFG open fryers Temperature probe SHORTED
E-10 Henny Penny OFE/OFG open fryers High limit has tripped
E-15 Henny Penny OFE/OFG open fryers Drain switch failure, or the drain is open while the fryer is on
E-20A Henny Penny OFE/OFG open fryers Air pressure switch stuck CLOSED (gas models)
E-20B Henny Penny OFE/OFG open fryers Draft fan or air pressure switch stuck OPEN (gas models)
E-20C Henny Penny OFE/OFG open fryers Ignition modules not responding (gas models)
E-20D Henny Penny OFE/OFG open fryers Pilots not lit, or no flame sense (gas models)
E-31 Henny Penny OFE/OFG open fryers Fan jumper wire missing
E-41 TO E-46 Henny Penny OFE/OFG open fryers Programming failure
E-47 Henny Penny OFE/OFG open fryers Analog converter chip or 12-volt supply failure
E-48 Henny Penny OFE/OFG open fryers Input system error
E-54 Henny Penny OFE/OFG open fryers PCB component failure
E-70 Henny Penny OFE/OFG open fryers Faulty power switch, its wiring, or the I/O board
E-92 Henny Penny OFE/OFG open fryers The 24-volt fuse on the I/O board has opened
E0 Hoshizaki FM-series flakers and F/FD modular flakers Ice making water leak
Hobart LXi/AM15 door dish machines Machine will not fill, or will not fill high enough. The cycle stops and the machine will not run
E01 Manitowoc Indigo/NXT/NEO cubers Long freeze cycle
Alto-Shaam Combitherm combi ovens Steam generator water fill fault
Beverage-Air WTR, UCR and HF cabinets Sensor S1 has failed, short or open. S1 is the air temperature probe
E1 Hoshizaki FM-series flakers and F/FD modular flakers Low ice production
True T-series and GDM reach-ins Cabinet temperature probe failure
Perlick BBS/SDB and HP-series units Probe reading out of range
Beverage-Air WTR, UCR and HF cabinets Sensor S1 has failed, short or open. S1 is the air temperature probe
Hatco Flav-R-Savor holding cabinets Air temperature sensor malfunctioning ON HOLDING CABINETS. On a Hydro-Heater it means something different: see below
Turbo Air Reach-ins and Merchandisers Depends entirely on which controller is fitted, and published sources contradict each other
Heatcraft Beacon II Walk-In Systems Sensor shorted, open or not installed: room, defrost and suction respectively
E01.0 Convotherm easyTouch combi steamers (OES, OEB, OGS, OGB) Not enough water reaching the appliance
E02 Manitowoc Indigo/NXT/NEO cubers Long harvest cycle
Alto-Shaam Combitherm combi ovens Control temperature high (CTP/CTC)
Beverage-Air WTR, UCR and HF cabinets Sensor S2 has failed, short or open. S2 is the evaporator coil probe used to terminate defrost
E2 Hoshizaki FM-series flakers and F/FD modular flakers Float switch error
Hobart LXi/AM15 door dish machines Machine will not fill, or will not fill high enough. The cycle stops and the machine will not run
Hobart LXi/AM15 door dish machines Fill did not complete: water failed to reach the tank float within 2.5 minutes (AM Select)
True T-series and GDM reach-ins Evaporator probe failure
Perlick BBS/SDB and HP-series units Defrost probe and third probe faulty
Stero SD3 door-type dish machines Water did not reach the float during fill within 150 seconds
Beverage-Air WTR, UCR and HF cabinets Sensor S2 has failed, short or open. S2 is the evaporator coil probe used to terminate defrost
Hatco Flav-R-Savor holding cabinets Humidity temperature sensor malfunctioning ON HOLDING CABINETS. On a Hydro-Heater it is the control probe: see below
Turbo Air Reach-ins and Merchandisers The clearest example of the contradiction, and worth checking carefully
Heatcraft Beacon II Walk-In Systems Sensor shorted, open or not installed: room, defrost and suction respectively
E02.0 Convotherm easyTouch combi steamers (OES, OEB, OGS, OGB) Excessive temperature in the wiring space
E03 Manitowoc Indigo/NXT/NEO cubers Input power loss
Frymaster M3000 controller fryers Temperature probe failure
Alto-Shaam Combitherm combi ovens Fan motor error (CTP/CTC)
Beverage-Air WTR, UCR and HF cabinets Sensor S3 has failed, short or open
E3 Hoshizaki FM-series flakers and F/FD modular flakers Gear motor error or gear motor sensor circuit open
Hobart LXi/AM15 door dish machines Machine will not fill, or will not fill high enough. The cycle stops and the machine will not run
True T-series and GDM reach-ins Auxiliary or display probe failure
Perlick BBS/SDB and HP-series units Defrost probe and third probe faulty
Beverage-Air WTR, UCR and HF cabinets Sensor S3 has failed, short or open
Hatco Flav-R-Savor holding cabinets The low water probe has not been satisfied and the heating elements are not yet submersed
Heatcraft Beacon II Walk-In Systems Sensor shorted, open or not installed: room, defrost and suction respectively
E03.X Convotherm easyTouch combi steamers (OES, OEB, OGS, OGB) Frequency converter fault
E04 Manitowoc Indigo/NXT/NEO cubers High condenser temperature or water condenser fault
Frymaster M3000 controller fryers High limit reading out of range
Alto-Shaam Combitherm combi ovens Lower fan motor error, two-motor models (CTP/CTC)
Beverage-Air WTR, UCR and HF cabinets Sensor S4 has failed, short or open
E4 Hoshizaki FM-series flakers and F/FD modular flakers Abnormal high side pressure
Hobart LXi/AM15 door dish machines Machine will not fill, or will not fill high enough. The cycle stops and the machine will not run
Beverage-Air WTR, UCR and HF cabinets Sensor S4 has failed, short or open
Heatcraft Beacon II Walk-In Systems Suction pressure transducer shorted, open or not installed
E05 Manitowoc Indigo/NXT/NEO cubers High-pressure control opened
Frymaster M3000 controller fryers High limit temperature exceeded
Alto-Shaam Combitherm combi ovens VFD communication failure (CTP/CTC)
E5 Hoshizaki FM-series flakers and F/FD modular flakers Gear motor drive element error
Hobart LXi/AM15 door dish machines Machine will not drain, or is filling too high and leaking from the door
Heatcraft Beacon II Walk-In Systems Outdoor temperature sensor shorted
E06 Frymaster M3000 controller fryers Heating failure
Alto-Shaam Combitherm combi ovens VFD communication failure, second drive (CTP/CTC)
E6 Hobart LXi/AM15 door dish machines Control fault with no operator remedy published (AM Select)
Stero SD3 door-type dish machines The float and temperature thermistors could not be detected at all
Turbo Air Reach-ins and Merchandisers Fault in the real-time clock
Heatcraft Beacon II Walk-In Systems Low superheat during cooling, held at 0F for two minutes
E07 Manitowoc Indigo/NXT/NEO cubers Starving TXV or low refrigerant charge
E7 Hobart LXi/AM15 door dish machines Water sensors need cleaning
Heatcraft Beacon II Walk-In Systems Compressor shutdown on a safety: high pressure, low pressure or oil pressure
E08 Manitowoc Indigo/NXT/NEO cubers TXV fault
Frymaster M3000 controller fryers ATO board error: the controller has lost contact with the automatic top-off board
E8 Hoshizaki FM-series flakers and F/FD modular flakers Discharge pipe temperature fault
E09 Manitowoc Indigo/NXT/NEO cubers Flooding evaporator TXV fault
Frymaster M3000 controller fryers Top-off pump not filling
E9 Heatcraft Beacon II Walk-In Systems Multi-in to multi-out communication wiring error between evaporator boards
E10 Manitowoc Indigo/NXT/NEO cubers Flooding evaporator TXV fault
Frymaster M3000 controller fryers Drain valve not open
E11 Manitowoc Indigo/NXT/NEO cubers Refrigeration fault
Frymaster M3000 controller fryers Drain valve not closed
E12 Manitowoc Indigo/NXT/NEO cubers Curtain switch open more than 24 hours
Frymaster M3000 controller fryers Return valve not open
E13 Frymaster M3000 controller fryers Return valve not closed
E13.0 Convotherm easyTouch combi steamers (OES, OEB, OGS, OGB) Steam generator thermoelement, excessive temperature
E15 Manitowoc Indigo/NXT/NEO cubers Low ambient control fault
E16 Manitowoc Indigo/NXT/NEO cubers Remote condenser fault
Frymaster M3000 controller fryers Filtration (AIF) probe error
E17 Frymaster M3000 controller fryers Top-off (ATO) probe error
E19 Manitowoc Indigo/NXT/NEO cubers Ice thickness probe fault
E20 Manitowoc Indigo/NXT/NEO cubers Water system fault
Frymaster M3000 controller fryers Invalid code location: the SD card was removed during a software upgrade
E21 Frymaster M3000 controller fryers Filter pad procedure error
E21 TO E24 Manitowoc Indigo/NXT/NEO cubers Temperature sensor fault (T1 through T4)
E22 Frymaster M3000 controller fryers Oil in pan error
E25 Manitowoc Indigo/NXT/NEO cubers Bin level probe low sensor fault
Frymaster M3000 controller fryers Recovery fault
E26 Manitowoc Indigo/NXT/NEO cubers Bin level probe fault, medium (E26) and high (E27) sensor
E27 Manitowoc Indigo/NXT/NEO cubers Bin level probe fault, medium (E26) and high (E27) sensor
Frymaster M3000 controller fryers Low temperature alarm: oil is roughly 35F below setpoint
Turbo Air Reach-ins and Merchandisers Sensor errors on specific inputs: S5, Sair and Saux respectively
E27.0 Convotherm easyTouch combi steamers (OES, OEB, OGS, OGB) Safety temperature limiter, B8 thermoelement, excessive temperature
E28 Manitowoc Indigo/NXT/NEO cubers AUCS board not detected
Frymaster M3000 controller fryers High temperature alarm
E29 Manitowoc Indigo/NXT/NEO cubers USB communication or download fault
Turbo Air Reach-ins and Merchandisers Sensor errors on specific inputs: S5, Sair and Saux respectively
E30 Manitowoc Indigo/NXT/NEO cubers USB communication or download fault
Turbo Air Reach-ins and Merchandisers Sensor errors on specific inputs: S5, Sair and Saux respectively
E31 Manitowoc Indigo/NXT/NEO cubers Safe mode
E32 Manitowoc Indigo/NXT/NEO cubers RS485 communication fault
E33 Manitowoc Indigo/NXT/NEO cubers Touchscreen fault
E34 Manitowoc Indigo/NXT/NEO cubers Display fault
E36 Manitowoc Indigo/NXT/NEO cubers Checksum error
E37 Manitowoc Indigo/NXT/NEO cubers Watchdog event
E53 Alto-Shaam Combitherm combi ovens Fan motor temperature error (CTP/CTC)
E54 Alto-Shaam Combitherm combi ovens Lower fan motor temperature error, two-motor models (CTP/CTC)
E88 Alto-Shaam Combitherm combi ovens Gas burner failed to ignite
E89 Alto-Shaam Combitherm combi ovens Gas burner failed to ignite
E100 Alto-Shaam Combitherm combi ovens Maintenance reminder past due
E101 Merrychef eikon speed ovens Magnetron failed to energise
E102 Merrychef eikon speed ovens Heater turned ON WITHOUT REQUEST on the e2 family
E103 Merrychef eikon speed ovens Ambient overheat, 70C
E104 Merrychef eikon speed ovens Magnetron or cavity overheat
E105 Alto-Shaam Combitherm combi ovens Low water pressure or no water
Merrychef eikon speed ovens Supply voltage high or low, OR supply frequency high or low, depending on the model
E106 Merrychef eikon speed ovens Cavity reached 25C above setpoint after it had been controlling at temperature
E108 Merrychef eikon speed ovens QTS personality module failed, wrong module, or none fitted
E114 Merrychef eikon speed ovens Spare, not used
E115 Merrychef eikon speed ovens Convection fan failed
EA True T-series and GDM reach-ins External alarms of three severities, from a digital input
Perlick BBS/SDB and HP-series units External alarms of three severities, from a digital input
ED Hobart LXi/AM15 door dish machines Slow leak: the tank is losing water (AM Select)
Stero SD3 door-type dish machines Slow leak: the machine refilled three times within 35 minutes of the initial fill
EE Hobart LXi/AM15 door dish machines Final rinse never reached temperature: the booster did not hit setpoint within 8 minutes after initial fill (AM Select)
True T-series and GDM reach-ins Power interruption during fast chill, clock settings lost, memory corruption
Stero SD3 door-type dish machines The booster did not reach temperature within eight minutes of the initial fill
EF Stero SD3 door-type dish machines Severe internal control error
ELECTRICAL LOSS Traulsen Intela-Traul reach-ins Power loss: the unit lost power and the control is flagging it on return
ERROR 1 Ice-O-Matic CIM and Elevation cubers Maximum freeze or maximum harvest exceeded: Power LED quick flashing red
ERROR 2 Ice-O-Matic CIM and Elevation cubers Thermistor failure: Power LED slow flashing, shown in the off state only
ERROR 3 Ice-O-Matic CIM and Elevation cubers Maximum fill or maximum purge exceeded: Power LED red and Clean LED yellow, both quick flashing
F Scotsman Prodigy series cubers The letters the display shows in normal operation
Scotsman Flaker/nugget machines Freeze mode: the machine is making ice
Stero SD3 door-type dish machines The control keeps the most recent machine fault in service diagnostics even after a power cycle clears the display
F1 TurboChef Tornado rapid cook ovens Blower running status bad
Jackson NXP door-type dish machines The booster is calling for heat with no water in it, which the control blocks to protect the element
Turbo Air Reach-ins and Merchandisers F-sensor and D-sensor malfunction respectively
F2 TurboChef Tornado rapid cook ovens Cook temperature low
Jackson NXP door-type dish machines A heater contactor is not switching off when it should
F3 TurboChef Tornado rapid cook ovens Magnetron current low
Jackson NXP door-type dish machines The machine could not fill
F4 TurboChef Tornado rapid cook ovens Door monitor defective
Jackson NXP door-type dish machines The machine is not receiving power correctly
F5 TurboChef Tornado rapid cook ovens Magnetron over temperature
Jackson NXP door-type dish machines The tank is not reaching temperature
F6 TurboChef Tornado rapid cook ovens Electrical compartment temperature high
Jackson NXP door-type dish machines Same fault as F1 but on the wash tank rather than the booster
F7 TurboChef Tornado rapid cook ovens Thermocouple open
TurboChef Tornado rapid cook ovens Two codes display on screen but are never counted, so the log understates what the oven has been doing
Jackson NXP door-type dish machines A heater contactor is not switching off when it should
F8 TurboChef Tornado rapid cook ovens Heat low fault
Jackson NXP door-type dish machines The machine could not fill
F9 Jackson NXP door-type dish machines The machine is not receiving power correctly
F10 Jackson NXP door-type dish machines The tank is not reaching temperature
F11 Jackson NXP door-type dish machines A specific probe has failed
F12 Jackson NXP door-type dish machines A specific probe has failed
F13 Jackson NXP door-type dish machines The display board and the IO module have stopped talking
F14 Jackson NXP door-type dish machines The machine is not seeing the water pressure it needs
F15 Jackson NXP door-type dish machines The machine could not meet its sanitising requirement
F16 Jackson NXP door-type dish machines A low liquid level control fault
F17 Jackson NXP door-type dish machines The incoming water supply is too hot
FF True T-series and GDM reach-ins Power interruption during fast chill, clock settings lost, memory corruption
FILL TIME TOO LONG Bunn Axiom and Infusion Series ICB digital-control brewers The tank is taking too long to refill
FILL1 Hobart LXi/AM15 door dish machines Fill fault on the LX40 family, equivalent to E0/E2/E3/E4
FILL2 Hobart LXi/AM15 door dish machines Fill fault on the LX40 family, equivalent to E0/E2/E3/E4
FILL3 PRBLM Hobart LXi/AM15 door dish machines Fill fault on the LX40 family, equivalent to E0/E2/E3/E4
FRYER WILL BECOME INOPERABLE Pitco Solstice and SG/SSH fryers Scrolling confirmation prompt during a blocked-drain lockout
GREEN OFF Gaylord CG3-UVi water-wash ventilators UV system in standby and not operating
Gaylord CG3-UVi water-wash ventilators No power reaching the UV ballast
GREEN ON Gaylord CG3-UVi water-wash ventilators One or more UV lamps are not working
H Scotsman Prodigy series cubers The letters the display shows in normal operation
HA True T-series and GDM reach-ins thi: highest temperature recorded in the LAE log. HA: live high temperature alarm on Dixell models
Perlick BBS/SDB and HP-series units Dixell controller: maximum temperature alarm
HEATING TIME TOO LONG Bunn Axiom and Infusion Series ICB digital-control brewers The tank is heating but not getting there
HELP Garland MCO convection ovens The control has a fault it cannot narrow down, and Garland lists three very different causes
HI True T-series and GDM reach-ins Cabinet high temperature alarm (LAE)
Vulcan VK/TR and ER/GR fryers Oil at 415F or above
Pitco Solstice and SG/SSH fryers Oil at an unsafe temperature
Beverage-Air WTR, UCR and HF cabinets Cabinet temperature too warm
HI TEMP Frymaster M3000 controller fryers Three separate over-temperature messages that are easy to confuse
Garland MCO convection ovens The oven is more than 50F above its setpoint, and the heaters have been cut
HIGH LIMIT FAILURE Frymaster M3000 controller fryers Three separate over-temperature messages that are easy to confuse
HIGH TEMP Vulcan VK/TR and ER/GR fryers Oil at 415F or above
HIGH TEMP! Star SCT4000 Contact Toasters Measured temperature is 75F (42C) or more ABOVE the set point
HIGH TMP Vulcan VK/TR and ER/GR fryers Oil at 415F or above
HOT HI-1 Frymaster M3000 controller fryers Three separate over-temperature messages that are easy to confuse
IGNITION FAILURE Pitco Solstice and SG/SSH fryers Burner failed to prove flame
IGNITION LOCKOUT Vulcan VK/TR and ER/GR fryers The fryer could not establish or prove a flame
L Scotsman Prodigy series cubers The letters the display shows in normal operation
Scotsman Flaker/nugget machines Board locked, buttons ignored
LA True T-series and GDM reach-ins tLo: lowest temperature recorded in the LAE log. LA: live low temperature alarm on Dixell models
Perlick BBS/SDB and HP-series units Dixell controller: minimum temperature alarm
LEA Beverage-Air WTR, UCR and HF cabinets Compressor run time too long
LO True T-series and GDM reach-ins Cabinet low temperature alarm (LAE)
Pitco Solstice and SG/SSH fryers Oil below the ready temperature
Beverage-Air WTR, UCR and HF cabinets Cabinet temperature too cold
LO H2O Hatco Flav-R-Savor holding cabinets The low water probe cannot detect water
LOC True T-series and GDM reach-ins Keypad locked (LAE)
Heatcraft Beacon II Walk-In Systems Not a fault. The board is locked and settings cannot be changed
LOC OUT Baxter OV500 rotating rack ovens Kosher lock-out: the oven fell below 150F and the control has disabled itself
LOW LIQ TEMP Manitowoc Indigo/NXT/NEO cubers Low ambient control fault
LOW TEMP! Star SCT4000 Contact Toasters After preheat, temperature stayed 50F (28C) or more BELOW set point for more than 15 minutes
LP FAIL Lincoln Impinger Conveyor Ovens Thermocouple failure, and the letters say WHICH SIDE
MELT Vulcan VK/TR and ER/GR fryers NOT A FAULT. The melt cycle is running, which is the first stage of heating solid shortening
MELT CYCLE Vulcan VK/TR and ER/GR fryers NOT A FAULT. The melt cycle is running, which is the first stage of heating solid shortening
NO OR LOW GAS SUPPLY Vulcan VK/TR and ER/GR fryers The fryer could not establish or prove a flame
O Scotsman Prodigy series cubers The letters the display shows in normal operation
Scotsman Flaker/nugget machines Machine switched off at the controller
OFF True T-series and GDM reach-ins Controller in standby, refrigeration off (LAE)
True T-series and GDM reach-ins External alarms of three severities, from a digital input
Perlick BBS/SDB and HP-series units External alarms of three severities, from a digital input
Garland MCO convection ovens Not a fault. The oven is off and has cooled below 150F, so the fan relay has opened
Heatcraft Beacon II Walk-In Systems NOT FAULTS. These are the eight normal operating modes
OP J1 Hobart LXi/AM15 door dish machines Control fault on the LX40 family, equivalent to E6
OPD Beverage-Air WTR, UCR and HF cabinets Door is open
OPEN PROBE Vulcan VK/TR and ER/GR fryers Temperature probe circuit open
Southbend Convection Oven The RTD temperature probe reads open
P1 Hobart LXi/AM15 door dish machines Tank temperature probe out of range
True T-series and GDM reach-ins Cabinet temperature probe failure
Perlick BBS/SDB and HP-series units Dixell controller: probe failure
Stero SD3 door-type dish machines Wash tank thermistor open or shorted
P2 Hobart LXi/AM15 door dish machines Tank temperature probe out of range
True T-series and GDM reach-ins Evaporator probe failure
Stero SD3 door-type dish machines Rinse thermistor open or shorted
P3 Hobart LXi/AM15 door dish machines Rinse temperature probe out of range
True T-series and GDM reach-ins Auxiliary or display probe failure
Stero SD3 door-type dish machines Booster thermistor open or shorted
PDN Heatcraft Beacon II Walk-In Systems NOT FAULTS. These are the eight normal operating modes
PLEASE REPAIR Bunn Axiom and Infusion Series ICB digital-control brewers The last of the three lime warnings; flow is now badly restricted
PRBLM DR2 Hobart LXi/AM15 door dish machines Drain fault on the LX40 family, equivalent to E5
PROB Vulcan VK/TR and ER/GR fryers Temperature probe circuit open
PROBE Hobart LXi/AM15 door dish machines Temperature probe fault on the LX40 family, equivalent to P1/P2/P3
PROBE ERROR Garland MCO convection ovens The control is receiving no signal at all from the temperature probe
PROBE FAIL Lincoln Impinger Conveyor Ovens The thermocouple has failed or become disconnected from the oven control
PROBE OP Pitco Solstice and SG/SSH fryers Digital controller: the temperature probe circuit reads open
PROBE OPEN Vulcan VK/TR and ER/GR fryers Temperature probe circuit open
PROBE SHORT Vulcan VK/TR and ER/GR fryers Temperature probe shorted
RESET Scotsman Prodigy series cubers Control sequences worth knowing before assuming a board has failed
RMT CND TEMP Manitowoc Indigo/NXT/NEO cubers Remote condenser fault
RP FAIL Lincoln Impinger Conveyor Ovens Thermocouple failure, and the letters say WHICH SIDE
RTC True T-series and GDM reach-ins Power interruption during fast chill, clock settings lost, memory corruption
RTD OPEN! Star SCT4000 Contact Toasters The RTD temperature probe circuit is open
RTD SHORT! Star SCT4000 Contact Toasters The RTD temperature probe circuit is shorted
RUN ERR Traulsen Intela-Traul reach-ins Run error: the compressor has run continuously for more than 24 hours
SER Heatcraft Beacon II Walk-In Systems NOT FAULTS. These are the eight normal operating modes
SERVER NOT IN PLACE Bunn Axiom and Infusion Series ICB digital-control brewers The brewer will not start because it cannot see a server under the funnel
SERVICE 10 Rational SCC series combi ovens Self-clean water not pumped out
SERVICE 11 Rational SCC series combi ovens Water metering sensor over-reading during steam generator fill
SERVICE 12 Rational SCC series combi ovens CDS sensor giving no output signal
SERVICE 13 Rational SCC series combi ovens Steam generator not refilling during steam mode
SERVICE 14 Rational SCC series combi ovens Level electrode not recognising water
SERVICE 16 Rational SCC series combi ovens Software version too old for the function requested
SERVICE 17 Rational SCC series combi ovens External EEPROM faulty
SERVICE 21 Rational SCC series combi ovens Voltage or current monitoring error on the main control board
SERVICE 23 Rational SCC series combi ovens Solid state relay short circuit, steam
SERVICE 24 Rational SCC series combi ovens Solid state relay short circuit, hot air
SERVICE 25 Rational SCC series combi ovens No water flow detected during CleanJet
SERVICE 26 Rational SCC series combi ovens Drain valve permanently closed
SERVICE 27 Rational SCC series combi ovens Drain valve will not close, CleanJet unavailable
SERVICE 28 Rational SCC series combi ovens Steam generator over temperature
SERVICE 29 Rational SCC series combi ovens Control board over temperature
SERVICE 30 Rational SCC series combi ovens Running in emergency humidity control
SERVICE 31.X Rational SCC series combi ovens Core probe faulty, with the digit naming which probe
SERVICE 32.X Rational SCC series combi ovens Ignition box faulty
SERVICE 33.X Rational SCC series combi ovens Repeated ignition resets without success
SERVICE 34.X Rational SCC series combi ovens Bus signal error, with the digit naming the device
SERVICE 35 Rational SCC series combi ovens Bus signal cannot be processed because the UltraVent is disconnected
SERVICE 36 Rational SCC series combi ovens Differential pressure sensor P1 faulty or out of range
SERVICE 37 Rational SCC series combi ovens Differential pressure sensor P1 faulty or out of range
SERVICE 40 Rational SCC series combi ovens Care Control fault
SERVICE REQUIRED Frymaster M3000 controller fryers A fault has occurred that needs a technician, and the controller is asking whether to keep cooking
SHDN Baxter OV500 rotating rack ovens The safety alarm has shut the oven down after the probe read 570 to 600F for ten seconds
SHORTED PROBE Vulcan VK/TR and ER/GR fryers Temperature probe shorted
Southbend Convection Oven The RTD temperature probe reads shorted
SN1 Traulsen Intela-Traul reach-ins Sensor failure, shown on the display
SN2 Traulsen Intela-Traul reach-ins Sensor failure, shown on the display
SN3 Traulsen Intela-Traul reach-ins Sensor failure, shown on the display
SOLID LOW WATER LED Follett Horizon Elite Chewblet ice machines A soft error: the machine did not detect water within 60 seconds of power-on
SUMP LEVEL SENSOR Hobart LXi/AM15 door dish machines Sump pressure switch out of range
SYSTEM FAILURE Pitco Solstice and SG/SSH fryers Digital controller: the temperature probe circuit reads shorted
TEMP SENSOR OUT OF RANGE Bunn Axiom and Infusion Series ICB digital-control brewers The temperature sensor circuit reads open
Bunn Axiom and Infusion Series ICB digital-control brewers The temperature sensor circuit reads shorted
TEMPERATURE TOO LOW Bunn Axiom and Infusion Series ICB digital-control brewers Tank water has not reached ready temperature
TLO True T-series and GDM reach-ins tLo: lowest temperature recorded in the LAE log. LA: live low temperature alarm on Dixell models
TOO MUCH LIME PLEASE REPAIR Bunn Axiom and Infusion Series ICB digital-control brewers Scale has progressed far enough that brew volume is no longer reliable
TST Heatcraft Beacon II Walk-In Systems NOT FAULTS. These are the eight normal operating modes
UHI Beverage-Air WTR, UCR and HF cabinets Line voltage too high
ULI Beverage-Air WTR, UCR and HF cabinets Line voltage too low
UPDT-FAIL-USB-ERR Baxter OV500 rotating rack ovens A firmware or recipe update from USB failed
WARNING INACCURATE FLOW Bunn Axiom and Infusion Series ICB digital-control brewers Scale has progressed far enough that brew volume is no longer reliable
WARNING VERY LOW FLOW Bunn Axiom and Infusion Series ICB digital-control brewers The last of the three lime warnings; flow is now badly restricted
YELLOW OFF Gaylord CG3-UVi water-wash ventilators UV system in standby and not operating
YELLOW ON Gaylord CG3-UVi water-wash ventilators One or more UV lamps are not working
Gaylord CG3-UVi water-wash ventilators No power reaching the UV ballast

Codes that are not in this list

Several makes report faults without a short code: Berkel counts flashes of a pilot light, Gaylord uses three status lights read in combination, Baxter uses beep patterns and an LED inside the control box, and Traulsen names alarm conditions. Those cannot be looked up by number and live on their brand pages instead.

Every meaning here is paraphrased from the manufacturer's own service documentation. Where a manufacturer's PDF lost a row or a column in extraction, the brand page says which part is missing rather than filling it with a guess.

Last updated August 22, 2026