Delfield MCII Error Codes

Applies to: MCII Tempatrol, and 6000XL/6100XL reach-ins. Compiled and paraphrased from Delfield's own manuals, published by The Delfield Company: the Service and Installation Manual for the ACR-26S with MCII Tempatrol, and the 6000XL and 6100XL Series Service, Installation and Care Manual, which supplies the up-to-ten-minute start-up delay, the behaviour of E-codes on that control and the control and serial number locations. Temperatures and intervals are Delfield's published figures. NOT REPRODUCED HERE: a per-code table for the 6000XL E-codes. Delfield does not publish one in these manuals, a parts distributor does, and distributor-authored code lists are not used on this site however convenient they would be. If a Delfield document with that table is found, this page gains it. Table last updated Aug 16, 2026.

How to read the codes

Delfield calls these refrigerators and freezers; most kitchens call them fridges, reach-ins or prep tables, and the controls are the same. The MCII Tempatrol reports through FOUR NAMED INDICATOR LIGHTS rather than numbered codes on the front panel, plus a display that flashes. Two of the four are not faults at all. Numbered diagnostic codes do exist behind a diagnostic mode, but the code chart in Delfield's manual did not extract legibly for us, so those numbers are deliberately NOT reproduced here rather than guessed at; the entry below tells a technician how to reach them on the machine.

The codes

CodeMeaningLikely causesOperator-safe stepsTechnician work
CLEAN CONDENSER light A maintenance reminder on a 90-day timer, NOT a fault Ninety days have elapsed since the last reset. It does not measure the condenser and does not know whether it is dirty Clean the condenser fins, then press RESET to clear the light. Delfield asks for this every three months. Ignoring it is how a warm cabinet starts, and several manufacturers do not cover failures caused by a dirty coil Confirm the light was reset after the last clean, or it will mislead the next person
DOOR AJAR light A door is open, and after a delay the machine escalates Door genuinely open, a failed door switch, or a gasket or hinge holding it off the seal Close the door. If it stays open the display begins to FLASH, and after three minutes a loud beep sounds every three seconds. Pressing RESET silences it, but if the door is still open the whole cycle repeats, so silencing it is not fixing it If the light shows with the door shut, the door switch or its wiring is the fault rather than the door
Flashing display, no other indication Interior temperature is outside the set range Door left open, a large warm load, dirty condenser, or a refrigeration fault Check the door and the condenser first. Delfield's presets are 37F for refrigerators and 0F for freezers, and their recommended storage ranges are 35 to 40F and 0 to minus 5F. Check product temperatures with a separate thermometer while you work out which Verify set point and differential before assuming a fault; the alarm follows the set range, not a fixed number
CHECK SYSTEM light Delfield's own wording is that a potentially serious problem has occurred A fault the control has detected and logged as a numbered diagnostic code Delfield asks for immediate action to protect product temperature and for a qualified service agent to be called. Before you call, note anything else showing on the panel; do not clear codes Enter diagnostic mode and write the codes down BEFORE repairing, because Delfield requires error codes to be cleared after the repair and clearing them destroys the record. We do not reproduce the numbered chart here: it did not extract legibly from the manual
DEFROST light A defrost cycle is running. Not a fault Automatic, custom or manual defrost Nothing to do. Worth knowing that Delfield says refrigerator defrosts RARELY occur, because the control only defrosts when it detects poor efficiency, so frequent defrosting on a refrigerator is itself a signal Frequent refrigerator defrosts point at low set point, 34F or below, or unusually high room temperature. Freezer defrost is preset to setting 3 from the factory
Display reads L instead of a temperature The control settings are locked, not faulted Somebody locked the control to stop unsupervised changes to set point or defrost Not a fault and not a failure to be reported. It means set point cannot be changed without the unlock sequence Unlock via function 009, toggling between L for locked and U for unlocked
Unit not cooling, no light showing The cabinet is warm but the control is not reporting anything Power, set point, or airflow rather than the control Check the breaker and that the power switch is on, then the set point, then whether a large warm load went in recently. Delfield's air curtain cabinets hold 45F maximum with the door open at 70F ambient, so a genuinely warm box with the door shut is a fault Condenser condition, fan operation, then charge. The manual's own diagnostic guidance runs on superheat and temperature difference: check the evaporator for frost accumulation, evaporator airflow, frost returning to the compressor, and possible capillary restriction
Blank display for up to 10 minutes after power is restored NOT A FAULT, and the one most likely to be reported as a dead unit On 6000XL and 6100XL controls, at initial start-up or any time power is disconnected and reconnected, Delfield's control DELAYS ALL OPERATIONS FOR UP TO TEN MINUTES while it initialises parameters and confirms the temperature sensors and circuits are working. During that window the digital display shows NEITHER TEMPERATURE NOR ERRORS, and nothing runs until the self-check completes and the control switches on the evaporator fan, compressor and condenser fan. After a power cut, a working cabinet is indistinguishable from a dead one for ten minutes Wait the full ten minutes before concluding anything, especially after a storm or a breaker trip. Then check the display shows a temperature Rule this out before diagnosing a no-start. If the display is still blank after ten minutes with power confirmed at the unit, then it is a fault
E-codes on 6000XL and 6100XL (E 1 and similar) The display swaps the temperature read-out for an error read-out A different control from the MCII Tempatrol covered above. Delfield's own manual states the control circuits continually self-check, and that WHEN AN ERROR IS DISPLAYED THE REFRIGERATION AND CONTROLS SYSTEM SHOULD CONTINUE TO FUNCTION, though not at optimal performance. So an E-code here does not mean the box is warming: it means something has degraded while the cabinet keeps running, which is why these get ignored for weeks Delfield's published instruction is to contact Delfield Service whenever the display shows an error read-out. Do not wait for the product to warm up, because on this control it may not Individual E-code meanings for this range are not reproduced here because Delfield does not publish a per-code table in the manuals sourced; a parts distributor publishes one and it is not used, per the standing rule on distributor-authored lists
Where the control actually is Not a fault, but the thing a technician needs before anything else On 6000XL and 6100XL units the control sits in the control box in the TOP of the refrigerator, behind the removable louvered panel on the LEFT side. The serial number tag is inside the cabinet, also on the left, and Delfield asks for it on any parts or service call Have the serial number ready before you ring: it is inside the cabinet on the left Factory setting is mid-range, about -3F box temperature on freezers, adjusted clockwise for colder
Refrigerant-side work legally requires an EPA Section 608 certified technician, and opening electrical panels is technician work. When in doubt, record the code and the cycle behavior; that detail alone shortens the service call.

If this needs a refrigeration technician

7 companies in this directory name Delfield on their own site: that page shows who has been phone-confirmed, who publishes 24/7 cover, and what each puts in writing. Start there if the brand matters more than the city.

Two questions worth reading before you ring anyone: what to do first when a code appears and how to tell whether it is yours to fix.

Delfield is a Welbilt brand, and Welbilt runs one technical support line covering all of them. The number, and what they will and will not do for you, is worth reading before you ring: most will help a technician who is already on site and will not talk an operator through a repair.

Or browse refrigeration service companies by state:

Indiana: Evansville · Fort Wayne · Indianapolis · South Bend

Kentucky: Lexington · Louisville · Owensboro

Ohio: Akron · Canton · Cincinnati · Cleveland · Columbus · Dayton · Sandusky · Toledo · Upper Sandusky · Youngstown

Pennsylvania: Allentown · Altoona · Erie · Harrisburg · Lancaster · Pittsburgh · Scranton · Williamsport

West Virginia: Charleston · Clarksburg · Huntington · Martinsburg · Morgantown · Parkersburg · Wheeling

Related: the PM checklist that prevents the most common codes outright, and the operator guides for symptom-first diagnosis.

Not sure this is the right make? The lookup by code shows every make that uses a given code, and flags the ones that mean different things depending on the machine in front of you.

Last updated August 16, 2026