Hoshizaki KM ice machine Error Codes

Applies to: KM crescent cubers, J series. Compiled and paraphrased from Hoshizaki America's own service manuals for J-series modular crescent cubers, published on hoshizakiamerica.com: manual number 73230 (issued 10-29-2018, revised 5-12-2021) for the KM-350, KM-520 and KM-660 MAJ, MWJ and MRJ, and manual number 73213 (issued 1-30-2018, revised 11-23-2020) for the KM-901, KM-1100, KM-1340 and KM-1601MRJ3. Those manuals supply the alarm table and its trigger values, the cause list Hoshizaki prints beside each alarm, the reset rules, the freeze-time correction alarms (board 2A7664-02), the LED assignments and the bin control behaviour. Older KM boards and the stackable and self-contained models use the same beep convention but their manuals should be checked for differences; Hoshizaki FM flakers have their own table on this site. Table last updated Nov 6, 2026.

Not your model? Other Hoshizaki code tables: FM-series flakers and F/FD modular flakers, H-series stackable crescent cubers.

Machine down now? 16 companies in this directory name Hoshizaki on their own site, with who has been phone-confirmed and who covers nights. Or find an ice machine technician by city.

How to read the codes

Hoshizaki KM cubers do not show a code on a screen. The control board COUNTS BEEPS from its buzzer, and the count is the fault: one beep, two beeps or three beeps. Hoshizaki's alarm table also has two voltage alarms numbered 6 and 7, and on these the red POWER OK LED goes out rather than the buzzer sounding a pattern. The three beep alarms are MANUAL RESET: the machine stays off until someone presses ALARM RESET on the control board with the power on, after which it restarts at a one minute fill. The two voltage alarms clear THEMSELVES once the supply is back in range. Two of the three beep alarms only trip after the SAME PROBLEM IN TWO CYCLES IN A ROW, so by the time you hear them the machine has already failed twice. The board's LEDs are a second, underused diagnostic: each lights when its component is energised (LED 1 compressor, LED 2 fan motor and liquid line valve, LED 3 pump motor, LED 4 inlet water valve, LED 5 drain valve), so which ones are lit tells a technician which part of the cycle the machine is in. Large models with freeze-time correction add a blinking-LED alarm with no beep at all. Note that a machine that has simply stopped with the yellow BC LED on is usually not faulted: see the last entry.

The codes

CodeMeaningLikely causesOperator-safe stepsTechnician work
1 beep HIGH EVAPORATOR TEMPERATURE: above 127F (53C). Manual reset Hoshizaki's own cause list: a HARVEST PROBLEM such as a stuck hot gas valve or its relay, HOT WATER ENTERING THE UNIT, a stuck headmaster, or a shorted thermistor. The evaporator should never get that hot, so something is feeding it heat when it should be making ice Check that the machine's water supply is connected to the COLD line. A machine plumbed to hot water, or to a line that runs warm, can trip this on its own. Beyond that, the ALARM RESET button is on the control board behind the front panel, and Hoshizaki's manual warns of electric shock from live terminals there. Treat the reset as a technician's job, and do not keep resetting a recurring alarm Hot gas valve and relay, headmaster, thermistor. Confirm the water supply temperature
2 beeps HARVEST BACKUP TIMER: harvest longer than 20 MINUTES for TWO CYCLES IN A ROW. Manual reset The ice is not releasing. Hoshizaki's list: an open thermistor, the hot gas valve not opening, the TXV or liquid line valve leaking by, low refrigerant charge, an inefficient compressor, or the water regulating valve leaking by (water-cooled models) Scale on the evaporator also slows release, so check when the machine was last cleaned and descaled. The ALARM RESET button is on the control board behind the front panel, and Hoshizaki's manual warns of electric shock from live terminals there. Treat the reset as a technician's job, and do not keep resetting a recurring alarm Thermistor, hot gas valve, TXV and liquid line valve, charge, compressor
3 beeps FREEZE TIMER: freeze longer than the freeze timer setting for TWO CYCLES IN A ROW. Manual reset; the board shuts the icemaker down The machine cannot finish freezing. Hoshizaki's list starts with the FLOAT SWITCH STUCK CLOSED (UP), then the water valve or hot gas valve leaking by, the pump motor not pumping, a defective TXV, the liquid line valve not opening, low charge, the headmaster not bypassing, or an inefficient compressor. The freeze timer is set by dip switches on the board and defaults to 75 MINUTES on the KM-350 to KM-660 J series The float switch item is the one in your control: Hoshizaki says SCALE CAN MAKE THE FLOAT STICK and that the fix is cleaning, not adjustment. Keep to the cleaning schedule and check the water filter. The ALARM RESET button is on the control board behind the front panel, and Hoshizaki's manual warns of electric shock from live terminals there. Treat the reset as a technician's job, and do not keep resetting a recurring alarm Float switch first (clean it), then valves, pump motor and refrigeration
Type 6 (low voltage) Control voltage LOW: 92 VAC plus or minus 5% or less. RESETS AUTOMATICALLY The supply to the control is too low. Hoshizaki's note is that the red POWER OK LED TURNS OFF when the voltage protection operates The machine restarts by itself once voltage is back in range. If it keeps happening, the problem is the electrical supply, which is an electrician's job Measure supply voltage under load; check circuit and connections
Type 7 (high voltage) Control voltage HIGH: 147 VAC plus or minus 5% or more. RESETS AUTOMATICALLY The supply to the control is too high. Hoshizaki's manual says the control voltage safeties reset automatically when the voltage is corrected As with low voltage: it clears itself, and repeats point at the building supply Measure supply voltage; check transformer and circuit
Red POWER OK LED blinking FREEZE-TIME CORRECTION activated (large J-series models, board 2A7664-02) A no-beep alarm from the large-model manual. With S4 dip switch 7 ON, the board compares freeze times across cycles and runs a correction cycle when the difference passes a set value, from 254 seconds at 3 cycles up to 462 seconds at 10. The blinking LED records that a correction has happened Not an emergency on its own, but it means freeze times are drifting. Note it for the next service visit Investigate why freeze times vary: water supply, scale, refrigeration
Red POWER OK and yellow EXT HARVEST LEDs blinking Freeze-time correction for the THIRD time within 36 HOURS (large J-series models) The same condition as above, repeating. Hoshizaki treats three corrections in 36 hours as an alarm in its own right, needing a manual reset The ALARM RESET button is on the control board behind the front panel, and Hoshizaki's manual warns of electric shock from live terminals there. Treat the reset as a technician's job, and do not keep resetting a recurring alarm Same investigation as the single correction, now more urgent
Yellow BC LED on, machine stopped BIN CONTROL OPEN: the machine believes the bin is full. Usually NOT a fault The bin control sensor stops the machine when ice reaches it. Hoshizaki's timing: it shuts down 15 seconds after activation in fill, at the end of harvest, and in freeze either 15 seconds after activation or at the end of the next harvest, depending on the short-cycle timer. It restarts about 30 SECONDS after the sensor clears. The detection distance has three settings, and setting 1 is for standard bins; settings 2 and 3 are for dispensers If the bin is genuinely full, nothing is wrong. If it is NOT full and the yellow LED is on, something is in front of the sensor or the setting does not match the bin or dispenser it sits on. Clear the area and wait 30 seconds before calling anyone Bin control setting for the bin or dispenser type, sensor and its cable
Refrigerant-side work legally requires an EPA Section 608 certified technician, and opening electrical panels is technician work. When in doubt, record the code and the cycle behavior; that detail alone shortens the service call.

If this needs an ice machine technician

16 companies in this directory name Hoshizaki on their own site: that page shows who has been phone-confirmed, who publishes 24/7 cover, and what each puts in writing. Start there if the brand matters more than the city.

Two questions worth reading before you ring anyone: what to do first when a code appears and how to tell whether it is yours to fix.

Or browse ice machines service companies by state:

Indiana: Evansville · Fort Wayne · Indianapolis · South Bend

Kentucky: Bowling Green · Lexington · Louisville · Owensboro

Ohio: Akron · Canton · Cincinnati · Cleveland · Columbus · Dayton · Sandusky · Toledo · Upper Sandusky · Youngstown

Pennsylvania: Allentown · Altoona · Erie · Harrisburg · Lancaster · Pittsburgh · Scranton · Williamsport

West Virginia: Charleston · Martinsburg · Morgantown · Wheeling

Related: the PM checklist that prevents the most common codes outright, and the operator guides for symptom-first diagnosis.

Not sure this is the right make? The lookup by code shows every make that uses a given code, and flags the ones that mean different things depending on the machine in front of you.

Last updated November 6, 2026