Hobart CLeN dishwasher Error Codes
Applies to: CLeN rack conveyor dish machines. Compiled and paraphrased from Hobart's own Installation, Operation and Care of CLeN-Series Dishwashers manual, FORM F47607 (November 2021), published on hobartcorp.com, covering the CL44eN, CL54eN, CL64eN, CLPS66eN, CLPS76eN, CLPS86eN, CLCS66eN, CLCS76eN and CLCS86eN in BAS, EGR and ADV versions, plus the CL44eN-VL and CLPS66eN-VL ventless models. The manual supplies every message, its meaning, the operator action and the trigger values below. Hobart prints the two probe messages in slightly different forms (Probe Err for a tank, Probe Error for the final rinse); they are shown as Hobart prints them, except that the dash in the final rinse message is written here as a hyphen. Older CL models (CL44e and earlier, without the N) and newer CL-DWR touchscreen models have their own manuals; confirm against the one for your machine. Hobart's door-type AM16 and LXi/AM15 machines have separate tables on this site. Table last updated Nov 6, 2026.
Not your model? Other Hobart code tables: LXi/AM15 door dish machines, AM16 door-type dish machines.
Machine down now? 25 companies in this directory name Hobart on their own site, with who has been phone-confirmed and who covers nights. Or find a dish machine technician by city.
How to read the codes
Hobart's CLeN rack conveyors do not show numbered codes. They show PLAIN-TEXT MESSAGES on the display, and most of them are operator fixes: a door open, a rack at the end of the table, a conveyor jam, a water change. Three things catch crews out. First, a machine that seems dead is often just in ENERGY SAVER (press STOP) or has auto-timed out (press START or feed a rack): Hobart lists both as causes of no operation. Second, if Dirty Water Mode is set to Alert and Lockout, CHANGE WATER SOON gives you only 5 minutes before the machine refuses to run. Third, on ventless (VL) models a table limit trip does NOT restart by itself. Before reaching into the machine to clear a jam or check the pump intake, disconnect power: Hobart requires lockout/tagout for those checks and warns there may be more than one circuit.
The codes
| Code | Meaning | Likely causes | Operator-safe steps | Technician work |
|---|---|---|---|---|
| Door(s) Open | An inspection door is open | A door left open after cleaning or checking the tanks. The machine will not run, and will not fill, with a door open | Close all inspection doors | None |
| Unload Dishes | A rack has reached the end of the unload table and tripped the TABLE LIMIT SWITCH | Normal protection against racks piling up off the end of the table | Remove the rack. The machine carries on once the switch resets. On ventless (VL) models the machine stays off after a table limit trip and does NOT restart by itself: press START | None, unless the switch is stuck |
| Clear Conveyor Jam | The conveyor motor OVERLOAD has tripped and shut the conveyor off | A jammed rack or too heavy a load | Clear the jam, remove the rack, press START and rerun the rack. Disconnect power before reaching into the machine | Conveyor drive and overload, if it keeps tripping with no jam |
| Check Water Level | The tanks are not filling correctly | Hobart's checklist: a drain left open or blocked with debris, the water supply valve closed, or a standpipe not seated. Its no-fill list also includes a dirty line strainer, sticking fill floats and low supply pressure | Check the drains are closed and clear, check the water supply valve is open, then open the inspection doors and check the level: about ONE INCH BELOW THE TOP OF THE STRAINER PAN or higher. If the tanks still have not filled after ANOTHER 20 MINUTES, call Hobart service | Fill solenoid valve and floats |
| Probe Err - [Tank Name] | A fault with the LOWER FLOAT assembly in the tank named on the display | Usually a float that is damaged, stuck with debris, or not covered by enough water | Check the float is not visibly damaged and that there is enough water covering it. If that does not clear it, call service | Float assembly and its wiring |
| Fnl Rinse Temp Low | Final rinse temperature is low (models with a booster) | Hobart's list: the booster circuit breaker off or tripped, the booster OVERTEMP circuit tripped, or building water arriving below the minimum temperature. High-temperature machines need at least 180F (82C) at the final rinse | Check the booster breaker is on, check the incoming water meets the minimum. An overtemp trip, a temperature control adjustment or a failed booster is a job for Hobart service | Booster overtemp, temperature control and booster heater |
| Probe Error - FnlRns | A fault with the final rinse probe | Hobart's first check is the water supply to the final rinse booster | Make sure the supply water valve to the final rinse booster is open. If it is and the message stays, call service | Final rinse probe |
| Reset Required | The control needs a power reset | Hobart gives no cause beyond the reset itself | Press POWER to put the machine in Standby, WAIT AT LEAST 60 SECONDS, then power it back on. If it keeps coming back, call service | Control, if it repeats |
| Delime Recommended | Lime buildup is expected, worked out from your water hardness and how much final rinse water has been used | A maintenance reminder, not a fault | Inspect the inside of the machine and follow Hobart's deliming procedure. Wear PPE, and do not spray or wipe delimer on the outside of the machine, which can corrode it. The message is cleared afterwards in Manager Programming | None |
| Change Water Soon | Dirty Water Mode: the wash water is due a change | Shown when Dirty Water Mode is on (it is OFF from the factory). The timer runs 1 to 6 hours, default 4 | Drain and refill at the next opportunity. In Alert and Lockout mode, you have 5 MINUTES before the machine locks out | None |
| Water Change Req'd | Dirty Water Mode: the water must be changed | In Alert and Lockout mode the machine WILL NOT RUN until the tanks are drained and refilled | Drain all tanks and let the machine refill | None |
| Energy Save Active / Press STOP to Exit | NORMAL. Idle mode after a period of no use, with heat OFF | Energy Saver kicks in after 1 to 6 hours of inactivity (default 2). It is also on Hobart's list of reasons for a machine that appears dead | Press STOP to resume, and watch the temperatures come back up before running dishes | None |
| Ventless Shutdown | Ventless (VL) models: the ventless system has faulted | Hobart's checklist points at missing curtains, debris in the air channel, or lime scale and debris on the wash tank coil | Make sure all curtains are in place, the air channel is clear and the wash tank coil is clean. Then turn the machine off, wait one minute and turn it back on | Ventless system |
| Ventless Refrigerant Lo | Ventless (VL) models: refrigerant is low | A refrigeration fault. Not an operator fix | Contact Hobart service | Refrigerant circuit |
If this needs a dish machine technician
25 companies in this directory name Hobart on their own site: that page shows who has been phone-confirmed, who publishes 24/7 cover, and what each puts in writing. Start there if the brand matters more than the city.
Two questions worth reading before you ring anyone: what to do first when a code appears and how to tell whether it is yours to fix.
Or browse dish machines service companies by state:
Indiana: Evansville · Fort Wayne · Indianapolis · South Bend
Kentucky: Lexington · Louisville · Owensboro
Ohio: Akron · Cincinnati · Cleveland · Columbus · Dayton · Toledo · Upper Sandusky · Youngstown
Pennsylvania: Allentown · Altoona · Erie · Harrisburg · Lancaster · Pittsburgh · Scranton · Williamsport
West Virginia: Charleston · Clarksburg · Huntington · Martinsburg · Parkersburg · Wheeling
Related: the PM checklist that prevents the most common codes outright, and the operator guides for symptom-first diagnosis.
Not sure this is the right make? The lookup by code shows every make that uses a given code, and flags the ones that mean different things depending on the machine in front of you.