Rational iCombi combi oven Error Codes
Applies to: iCombi Pro and Classic. Compiled and paraphrased from Rational's own Original Instructions for Use, the problem-resolution chapters: iCombi Pro, document 20085 V-15 (07/25, en-US, covering the 20-half and 20-full size units), and iCombi Classic, document 20163 V-12 (07/25, en-US), both published by RATIONAL AG of Landsberg am Lech and distributed through Rational's dealers. The Classic manual supplies the on-screen titles quoted below. TWO DIFFERENCES BETWEEN THE MANUALS ARE PUBLISHED RATHER THAN RESOLVED: Service 28.4, which the iCombi Pro manual gives as the cooking cabinet temperature limit exceeded and the iCombi Classic manual titles Steam generator too cold, the minimum steam generator temperature not reached; and Service 34.8, after which the Pro manual says cooking is still possible and the Classic manual says it is not. Some codes appear in only one of the two manuals, and are marked. Codes and wording can change with software versions; confirm against the manual for your exact unit. Table last updated Nov 6, 2026.
Not your model? Other Rational code tables: SCC series combi ovens.
Machine down now? 4 companies in this directory name Rational on their own site, with who has been phone-confirmed and who covers nights. Or find a combi oven technician by city.
How to read the codes
The iCombi shows a fault as SERVICE plus a number, and the number after the dot matters: Service 42.1 and Service 42.4 share a cause but sit in different parts of the oven. Rational's own tables group every code by the system it belongs to (steam generator, hot air, humidity, cleaning, care, gas, and a general notification centre), and the same suffixes recur in each group: .1 in the steam generator table, .2 in humidity, .3 in hot air, .4 in care and .6 in cleaning, which is why Service 42.x and Service 43.x appear five times each. THE MOST USEFUL COLUMN IN RATIONAL'S TABLE IS WHETHER YOU CAN KEEP COOKING, and it has three answers: yes; ONLY HOT AIR MODE, which means dry convection still works but steam and combination cooking do not; or no. That one fact decides whether service continues tonight, so it is given for every code below. A message can be swiped aside while you wait for help; it then sits as a red symbol at the side of the display and a tap brings it back. Every message carries the unit's SERIAL NUMBER and SOFTWARE VERSION, and Rational asks for both when you call. On the iCombi Classic the code is followed by a short title on screen, such as Service 10 SC-automatic failed. These are iCombi codes; an older SelfCookingCenter (SCC) uses a different list with some of the same numbers meaning different things, so check which oven you have before reading across.
The codes
| Code | Meaning | Likely causes | Operator-safe steps | Technician work |
|---|---|---|---|---|
| Service 10 | SC automation malfunctioning (Classic title: SC-automatic failed). Cooking still possible | SC is Rational's automatic descaling and cleaning of the steam generator. The fault is in that automation, not in heating, which is why Rational still allows cooking | Keep cooking and book the service partner. Do not ignore it for weeks: the automation exists to keep scale out of the steam generator | Diagnose the SC automation and its pump before treating it as a heating fault |
| Service 11 | Steam generator water intake malfunctioning (Classic: Water supply steam generator failed). Cooking still possible | Water is not getting into the steam generator as expected | Check first that the water supply to the oven is turned on and the hose is not kinked. If the code stays, call the service partner | Inlet valve, supply pressure and the steam generator fill path |
| Service 12 | Water measurement system malfunctioning (Classic: Water volume measurement failed). Cooking still possible | The oven cannot measure the water going into the steam generator | Cooking can continue. Rational asks for every error message to go to your RATIONAL Service Partner. Have the serial number and software version ready: both are shown inside the error message itself | Water volume measurement components |
| Service 13 | Steam generator water level detection malfunctioning (Classic: Water detection failed). ONLY HOT AIR MODE available | The oven cannot tell how much water is in the steam generator, so it refuses to make steam rather than risk running it dry | Switch the menu to dry-heat (hot air) items for the rest of service; steam and combi programs will not run | Level detection in the steam generator, often scale-related |
| Service 17 | Unit model incorrect (Classic: Unit data failed). NO cooking | The controller does not recognise the unit type it is installed in. This is a configuration or electronics fault, not a component wearing out | Nothing for the operator to fix. Rational asks for every error message to go to your RATIONAL Service Partner. Have the serial number and software version ready: both are shown inside the error message itself | Unit data and controller configuration |
| Service 20.1 / 20.2 / 20.4 / 20.8 | A temperature probe is defective; the suffix says which one | Rational's tables place them as follows: 20.1 is the CABINET sensor in the hot air system (Classic: Cabinet sensor failed), and NO cooking is possible; 20.2 is the control sensor in the humidity system and 20.4 the humidity sensor, both of which still allow cooking; 20.8 is the STEAM GENERATOR sensor, and only hot air mode remains | Read the full number before deciding: 20.1 stops the oven, 20.2 and 20.4 do not, and 20.8 leaves you dry heat only | Probe replacement for the position the suffix identifies |
| Service 25 | Water quantity required by the iCareSystem is too low (iCombi Pro) | Appears in the cleaning table. The cleaning system did not receive the water it needs. Rational's table does not state whether cooking remains possible | Check the water supply is on. Rational asks for every error message to go to your RATIONAL Service Partner. Have the serial number and software version ready: both are shown inside the error message itself | Water supply to the iCareSystem and its fill path |
| Service 26 / Service 27 | Cleaning ball valve cannot find its OPEN (26) or CLOSED (27) position (iCombi Pro). NO cooking | A valve in the iCareSystem cleaning circuit is stuck or its position sensing has failed | Not an operator repair. Rational asks for every error message to go to your RATIONAL Service Partner. Have the serial number and software version ready: both are shown inside the error message itself | Ball valve actuator and position sensing |
| Service 28.1 / 28.2 / 28.4 | Temperature limit exceeded: steam generator (28.1), cooking cabinet (28.2), or 28.4 as described | 28.1 and 28.2 are over-temperature cut-outs in the hot air system and stop cooking entirely (Classic titles: Steam generator too hot, Cooking cabinet too hot). 28.4 is PUBLISHED DIFFERENTLY: the iCombi Pro manual gives it as the cooking cabinet temperature limit exceeded, while the iCombi Classic manual titles it Steam generator too cold, the minimum steam generator temperature not reached. Both manuals agree that with 28.4 only hot air mode remains | An over-temperature cut-out is a safety stop. Do not try to restart repeatedly. Rational asks for every error message to go to your RATIONAL Service Partner. Have the serial number and software version ready: both are shown inside the error message itself | Temperature limiters, heating control and, for 28.4, steam generator heating |
| Service 29 | Board temperature too high (Classic: Electric compartment too hot). NO cooking | The electronics are overheating. On any combi oven that usually comes back to ventilation around the unit | Check that nothing is blocking the air around and under the oven, that it is not boxed in by other equipment, and that the area is not unusually hot. Rational asks for every error message to go to your RATIONAL Service Partner. Have the serial number and software version ready: both are shown inside the error message itself | Electronics compartment cooling and fan |
| Service 30 | Humidity measurement incorrect (Classic: Humidity control failed). Cooking still possible | The oven cannot measure cabinet humidity correctly, so humidity-controlled results may drift | Cooking can continue; watch results on humidity-sensitive items. Rational asks for every error message to go to your RATIONAL Service Partner. Have the serial number and software version ready: both are shown inside the error message itself | Humidity measurement system |
| Service 31.1 / 31.2 | Core temperature probe defective. Cooking possible WITHOUT the probe | The probe you push into the food has failed (Classic titles: Core temperature sensor failed, and for 31.2 Core temperature sensor on emergency run). Rational's instructions also say to return the probe to its holder after use to avoid damaging it | Cook to time instead of core temperature and check food temperatures with a separate thermometer until it is replaced. Do not rely on a probe-driven program | Core probe and its connection |
| Service 32.1-32.3 / 33.1-33.3 | Gas burner faulty (gas units). NO cooking | Rational's manuals give the same cause for all six numbers: the gas burner is malfunctioning (Classic titles: Check gas supply for 32.x, Gas burner failed close gas supply for 33.x) | Rational's instruction for each of these is explicit: CLOSE THE SHUT-OFF VALVE ON THE GAS LINE. If you smell gas, do not switch lights or equipment on or off, ventilate, leave the building and call the gas company or fire department | Gas burner, ignition and gas supply. Gas work by a qualified technician only |
| Service 34.x | Internal data communication faulty; the suffix sets how serious it is | All 34.x messages are internal communication faults between the oven's electronics, but the consequence depends on the number. In the hot air table 34.1, 34.2 and 34.4 allow NO cooking. 34.16, 34.64 and 34.400 (notification centre) and 34.32 (gas units) still allow cooking. 34.8 appears in the cleaning table as the automatic clean does not work, and here the manuals DISAGREE: the iCombi Pro manual says cooking is still possible, the iCombi Classic manual says it is not | Note the exact number. A power cycle is reasonable once; repeated 34.x messages need the service partner | Board-to-board communication: connectors, cabling, controller |
| Service 36 / Service 37 | Differential pressure sensor defective. Cooking still possible | The sensor used in humidity control has failed (Classic titles: Humidity control failed for 36, Differential pressure sensor defective for 37) | Cooking can continue. Rational asks for every error message to go to your RATIONAL Service Partner. Have the serial number and software version ready: both are shown inside the error message itself | Differential pressure sensor and its tubing |
| Service 40 | Care liquid quantity required by the iCareSystem is too low (iCombi Pro). Cooking still possible | Appears in the care table. The care system did not get the care product it needs. The iCombi Pro uses care tabs in a care drawer and Active Green cleaner tabs in the drain sieve, and Rational says to use only its recommended tabs | Check the care tabs and care drawer are set up as the manual describes. If the code persists, rational asks for every error message to go to your RATIONAL Service Partner. Have the serial number and software version ready: both are shown inside the error message itself | Care dosing path and its water supply |
| Service 41 | Steam injection nozzle or pipe has SCALE. Steam injection not available | Scale has built up where steam is injected into the cabinet. Hard water and skipped care are the usual background | Rational's care schedule includes descaling the steam nozzle monthly, by soaking it in descaler until the scale dissolves. Ask the service partner whether that is the part involved before relying on it to clear this code | Descale nozzle and pipe; review water treatment |
| Service 42.x | Water supply faulty (Classic title: Solenoid valve failed); the suffix says where | Rational lists 42.1 in the steam generator table, where only hot air mode remains; 42.2 in humidity and 42.4 in care, both still able to cook; 42.3 in hot air, where steam injection is unavailable; and 42.6 in hot air, still able to cook | Check first that the water supply is on and the hose is not kinked. Then go by the suffix: 42.1 means dry heat only | Solenoid valve for the system the suffix identifies, and supply pressure |
| Service 43.x | Internal water supply NOT CLOSING (Classic title: Solenoid valve failed). Only hot air mode | A water valve is failing to shut. Rational lists it five times: 43.1 steam generator, 43.2 humidity, 43.3 hot air, 43.4 care and 43.6 cleaning, and in every case only hot air mode remains | A valve that will not close can keep letting water in. Watch for water where it should not be, use dry-heat cooking only, and call the service partner | Solenoid valve that is failing to close, identified by the suffix |
| Service 46.1 / 46.2 | Water supply malfunctioning, steam generator (Classic title: Pump failed). Cooking still possible | Both manuals list 46.1; the iCombi Classic manual also lists 46.2 with the same cause | Check the water supply is on. Rational asks for every error message to go to your RATIONAL Service Partner. Have the serial number and software version ready: both are shown inside the error message itself | Pump in the steam generator water path |
| Service 47.1 / 47.2 | Waste water pump defective. Cooking still possible | The pump that removes waste water, listed in the cleaning table | Cooking can continue, but watch for water not draining from the cabinet. Rational asks for every error message to go to your RATIONAL Service Partner. Have the serial number and software version ready: both are shown inside the error message itself | Waste water pump and drain path |
| Service 48.1 / 48.2 | Circulating pump defective (iCombi Pro). Cooking still possible | The pump that circulates cleaning fluid during automatic cleaning | Cooking can continue; automatic cleaning will be affected. Rational asks for every error message to go to your RATIONAL Service Partner. Have the serial number and software version ready: both are shown inside the error message itself | Circulation pump in the cleaning circuit |
| Service 49.1 / 49.2 | Water supply faulty, care system (Classic title: Pump failed). Cooking still possible | Listed in the care table | Check the water supply is on. Rational asks for every error message to go to your RATIONAL Service Partner. Have the serial number and software version ready: both are shown inside the error message itself | Care system pump and supply |
| Service 50 | Real time clock not initialised (iCombi Pro). Cooking still possible | The controller has lost the date and time | Rational's instruction is simply to SET THE DATE AND TIME. If it keeps returning, see Service 51 | Clock and its backup battery |
| Service 51 | Battery defective (iCombi Pro). Cooking still possible | The controller's backup battery has failed. A failing battery is the usual reason a clock keeps losing its setting | Cooking can continue. Rational asks for every error message to go to your RATIONAL Service Partner. Have the serial number and software version ready: both are shown inside the error message itself | Controller backup battery |
| Service 52.1 / 52.2 | Cooking cabinet lighting not working correctly (Classic: Cabinet light failed). Cooking still possible | The cabinet light has failed or is malfunctioning | No effect on cooking itself. Book it with the next service visit | Cabinet lighting and its supply |
| Service 60 | Ignition box initialisation defective (gas units; Classic title: Gas system failed) | The gas ignition control did not start up correctly | Rational's instruction: switch the unit off and on again, and if the error persists, call the service partner | Ignition box and gas system. Gas work by a qualified technician only |
| Service 72 | Activation temperature of a temperature probe exceeded (Classic: Safety temperature limiter has been triggered). NO cooking | A safety temperature limiter has tripped. This is a protection doing its job, and the question is why the temperature got there | Do not keep resetting a safety limiter. Rational asks for every error message to go to your RATIONAL Service Partner. Have the serial number and software version ready: both are shown inside the error message itself | Find the cause of the over-temperature before resetting the limiter |
| Service 110 | Fault in the SC pump DURING AUTOMATIC CLEANING. NO cooking | Listed in the cleaning table on both models (Classic title: Cleanjet failed). Note that the number is shared with older Rational ovens, where documentation describes Service 110 differently, so make sure you are reading the iCombi entry | If a power failure interrupted cleaning, Rational says cleaning resumes when power returns. If the oven shows Service 110, rational asks for every error message to go to your RATIONAL Service Partner. Have the serial number and software version ready: both are shown inside the error message itself | SC pump and the cleaning cycle |
| Service 120 | Fault in water level recognition DURING AUTOMATIC CLEANING. NO cooking | Listed in the cleaning table on both models (Classic title: Cleanjet failed) | If a cleaning has to be cancelled, Rational's procedure is to remove the cleaner tabs, open the door and rinse the cabinet with water to clear residue, close the door and let the cancellation finish. Then rational asks for every error message to go to your RATIONAL Service Partner. Have the serial number and software version ready: both are shown inside the error message itself | Water level recognition in the cleaning circuit |
| Service 121 | Pour water 3 l (iCombi Classic). Only hot air mode | The iCombi Classic manual gives the cause as not enough water in the cleaning agent box | The on-screen title is the instruction: add 3 litres of water as prompted. Rational's manuals also say to run the oven only with the water connected, because without it only dry heat is possible and the oven can overheat | Water supply to the cleaning agent box |
| Service 1017 | USB stick error (iCombi Classic). Cooking still possible | The USB stick in the unit is defective or unreadable | Try a different USB stick. Cooking is unaffected | None usually needed |
If this needs a combi oven technician
4 companies in this directory name Rational on their own site: that page shows who has been phone-confirmed, who publishes 24/7 cover, and what each puts in writing. Start there if the brand matters more than the city.
Two questions worth reading before you ring anyone: what to do first when a code appears and how to tell whether it is yours to fix.
Or browse combi ovens service companies by state:
Indiana: Evansville · Fort Wayne · Indianapolis · South Bend
Kentucky: Lexington · Louisville · Owensboro
Ohio: Akron · Canton · Cincinnati · Cleveland · Columbus · Dayton · Toledo · Upper Sandusky · Youngstown
Pennsylvania: Allentown · Altoona · Erie · Harrisburg · Lancaster · Pittsburgh · Scranton · Williamsport
West Virginia: Charleston · Clarksburg · Martinsburg · Morgantown · Parkersburg · Wheeling
Related: the PM checklist that prevents the most common codes outright, and the operator guides for symptom-first diagnosis.
Not sure this is the right make? The lookup by code shows every make that uses a given code, and flags the ones that mean different things depending on the machine in front of you.